Loop Gain Measurement of Paralleled DC-DC Converters With Average-Current-Sharing Control

Paralleled operation of dc-dc converters is widely used in today's distributed power systems. Special control circuitry is usually necessary to ensure current sharing among the paralleled modules. The average-current-sharing control method is very popular due to its simple implementation and go...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on power electronics 2008-11, Vol.23 (6), p.2942-2948
Hauptverfasser: Panov, Y., Jovanovic, M.M.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Paralleled operation of dc-dc converters is widely used in today's distributed power systems. Special control circuitry is usually necessary to ensure current sharing among the paralleled modules. The average-current-sharing control method is very popular due to its simple implementation and good performance. Although the analysis and design of the average-current-sharing control were presented in the past, a loop gain measurement technique has not been published. This paper presents a practical loop gain measurement technique that uses two excitation sources. Measured and theoretical data are compared to verify the proposed technique.
ISSN:0885-8993
1941-0107