Efficiency-Based Auto-Tuning of Current Sensing and Sharing Loops in Multiphase Converters
Multiphase converters require a current-sharing loop to maintain equal or desired current sharing between phases or paralleled modules. The current-sharing loop is highly sensitive to current-sensing accuracy. In this letter, a method is presented to achieve auto-tuning of the current-sharing loop i...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on power electronics 2008-03, Vol.23 (2), p.1009-1013 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Multiphase converters require a current-sharing loop to maintain equal or desired current sharing between phases or paralleled modules. The current-sharing loop is highly sensitive to current-sensing accuracy. In this letter, a method is presented to achieve auto-tuning of the current-sharing loop in multiphase converters while adaptively calibrating the current sensing based on power conversion efficiency. This is achieved without the need for a precise calibration reference or resistor and with no dependency on sensing accuracy. A digital controller implementation of the method is described and experimental results are obtained for a 0.84 V/30 A two-phase buck voltage regulator. |
---|---|
ISSN: | 0885-8993 1941-0107 |
DOI: | 10.1109/TPEL.2008.917808 |