Mechanistic modeling of cyclic voltammetry: A helpful tool for understanding biosensor principles and supporting design optimization

•Model parameters were either found in literature or estimated using experimental data in order to increase the applicability of the developed model.•Cyclic voltammetry model was applied for interpreting the experimental results at various designs and operating conditions of the biosensor.•Stability...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Sensors and actuators. B, Chemical Chemical, 2018-04, Vol.259, p.945-955
Hauptverfasser: Semenova, Daria, Zubov, Alexandr, Silina, Yuliya E., Micheli, Laura, Koch, Marcus, Fernandes, Ana C., Gernaey, Krist V.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:•Model parameters were either found in literature or estimated using experimental data in order to increase the applicability of the developed model.•Cyclic voltammetry model was applied for interpreting the experimental results at various designs and operating conditions of the biosensor.•Stability of the biosensor response was addressed modeling coupled with biosensor electrochemical and morphological characterization.•A more favourable design of the biosensor system was developed, which subsequently reduced the reagent usage and waste generation. Design, optimization and integration of biosensors hold a great potential for the development of cost-effective screening and point-of-care technologies. However, significant progress in this field can still be obtained on condition that sufficiently accurate mathematical models will be developed. Herein, we present a novel approach for the improvement of mechanistic models which do not only combine the fundamental principles but readily incorporate the results of electrochemical and morphological studies. The first generation glucose biosensors were chosen as a case study for model development and to perform cyclic voltammetry (CV) measurements. As initial step in the model development we proposed the interpretation of experimental voltammograms obtained in the absence of substrate (glucose). The model equations describe dynamic diffusion and reaction of the involved species (oxygen, oxidized/reduced forms of the mediator - Prussian Blue/Prussian White). Furthermore, the developed model was applied under various operating conditions as a crucial tool for biosensor design optimization. The obtained qualitative and quantitative dependencies towards amperometric biosensors design optimization were independently supported by results of cyclic voltammetry and multi-analytical studies, such as scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX) and liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS). Remarkably, a linear response of the optimized biosensors tested at the applied voltage (−0.14 V) in the presence of the glucose was obtained from 10−3 to 10−5 M (relative standard deviation (RSD)
ISSN:0925-4005
1873-3077
DOI:10.1016/j.snb.2017.12.088