Fire Performance of CFST Triple-Limb Laced Columns
AbstractThis paper investigates the fire performance of concrete-filled steel tubular (CFST) triple-limb laced columns. Six CFST triple-limb laced columns are tested to measure their fire resistance. The influence of column load ratio and steel type on fire resistance are investigated. For compariso...
Gespeichert in:
Veröffentlicht in: | Journal of structural engineering (New York, N.Y.) N.Y.), 2018-09, Vol.144 (9) |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | AbstractThis paper investigates the fire performance of concrete-filled steel tubular (CFST) triple-limb laced columns. Six CFST triple-limb laced columns are tested to measure their fire resistance. The influence of column load ratio and steel type on fire resistance are investigated. For comparison, four CFST single-limb columns in fire are tested. The test results indicate that the three CFST chords in CFST triple-limb laced columns can work together very well in fire because of the binding effect provided by the steel lacing tubes. Finite-element analysis (FEA) models are developed to simulate the CFST triple-limb laced columns in fire. The mechanical behavior, including failure modes, deformation, and load distribution, are discussed. Parametric analysis based on the established FEA model is conducted, and a simplified equation is proposed to predict the fire resistance of CFST triple-limb laced columns. |
---|---|
ISSN: | 0733-9445 1943-541X |
DOI: | 10.1061/(ASCE)ST.1943-541X.0002168 |