Capacitor Current Imbalance and Its Suppression Method Between Phase Legs for Three-phase Inverter

This paper proposes a method to suppress the capacitor current imbalance between the phase legs of a three-phase inverter circuit. This circuit consists of half-bridge modules and DC-link capacitors closely connected to each module. It can be designed for low stray inductance between power semicondu...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Denki Gakkai ronbunshi. D, Sangyō ōyō bumonshi 2018/06/01, Vol.138(6), pp.491-498
Hauptverfasser: Hirao, Takashi, Wada, Keiji, Shimizu, Toshihisa
Format: Artikel
Sprache:eng ; jpn
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This paper proposes a method to suppress the capacitor current imbalance between the phase legs of a three-phase inverter circuit. This circuit consists of half-bridge modules and DC-link capacitors closely connected to each module. It can be designed for low stray inductance between power semiconductor devices and DC-link capacitors in each module. However, in the conventional structure, the stray inductance between the phase legs may lead to an imbalance in the capacitor current due to the DC-side resonance phenomenon under a higher switching frequency condition by using a SiC MOSFET. This paper presents the analyses of the equivalent circuit considering the circuit configuration, which suggests that capacitor current imbalance occurs depending on the stray inductance between phase legs. To suppress the capacitor current imbalance, a delta-type bus bar connecting phase legs is proposed. The experiment results at 300V and 4.6A demonstrate the suppression effectiveness of the proposed method.
ISSN:0913-6339
2187-1094
1348-8163
2187-1108
DOI:10.1541/ieejias.138.491