Investigation on the effects of wall thickness and porous media on the thermal performance of a non-premixed hydrogen fueled cylindrical micro combustor
[Display omitted] •Combustion characteristic and thermal transmission in a cylindrical micro combustor are investigated.•Porous media and different wall thickness for combustor are used to enhance the heat transfer.•Thermal performance of outer wall and working performance are investigated.•Effects...
Gespeichert in:
Veröffentlicht in: | Energy conversion and management 2018-01, Vol.155, p.276-286 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | [Display omitted]
•Combustion characteristic and thermal transmission in a cylindrical micro combustor are investigated.•Porous media and different wall thickness for combustor are used to enhance the heat transfer.•Thermal performance of outer wall and working performance are investigated.•Effects of external thermal environment on the working performance of micro combustor are conducted.
An investigation on non-premixed H2/air combustion in a cylindrical micro combustor has been carried out. The effects of porous media and outer wall thickness on the combustion characteristics, flame location, thermal performance and energy conversion efficiency of the thermo photovoltaic (TPV) system were investigated. For the application of micro TPV system, a high and uniform outer wall temperature distribution is indispensable for the sustaining output, and the high energy efficiency is desirable. The results indicate that the setting of porous media or the increase of outer wall thickness can enhance the heat transfer in micro combustor and affects the flame stability, and the micro combustor with porous media and outer wall thickness b = 0.2 mm obtains the lowest flame location. They are also conducive to the improvement of outer wall temperature and energy efficiency, the outer wall temperature of the micro combustor with a thicker outer wall and porous media is relatively uniform and the energy conversion efficiency of micro TPV system is also improved, the micro combustor with b = 0.6 mm and porous media is more suitable for the application of micro TPV system. Additionally, the external thermal environment also can improve the outer wall temperature profile and the working performance of the micro combustor. |
---|---|
ISSN: | 0196-8904 1879-2227 |
DOI: | 10.1016/j.enconman.2017.10.095 |