Porous Structure Reconstruction Using Convolutional Neural Networks

The three-dimensional high-resolution imaging of rock samples is the basis for pore-scale characterization of reservoirs. Micro X-ray computed tomography (µ-CT) is considered the most direct means of obtaining the three-dimensional inner structure of porous media without deconstruction. The micromet...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Mathematical geosciences 2018-10, Vol.50 (7), p.781-799
Hauptverfasser: Wang, Yuzhu, Arns, Christoph H., Rahman, Sheik S., Arns, Ji-Youn
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The three-dimensional high-resolution imaging of rock samples is the basis for pore-scale characterization of reservoirs. Micro X-ray computed tomography (µ-CT) is considered the most direct means of obtaining the three-dimensional inner structure of porous media without deconstruction. The micrometer resolution of µ-CT, however, limits its application in the detection of small structures such as nanochannels, which are critical for fluid transportation. An effective strategy for solving this problem is applying numerical reconstruction methods to improve the resolution of the µ-CT images. In this paper, a convolutional neural network reconstruction method is introduced to reconstruct high-resolution porous structures based on low-resolution µ-CT images and high-resolution scanning electron microscope (SEM) images. The proposed method involves four steps. First, a three-dimensional low-resolution tomographic image of a rock sample is obtained by µ-CT scanning. Next, one or more sections in the rock sample are selected for scanning by SEM to obtain high-resolution two-dimensional images. The high-resolution segmented SEM images and their corresponding low-resolution µ-CT slices are then applied to train a convolutional neural network (CNN) model. Finally, the trained CNN model is used to reconstruct the entire low-resolution three-dimensional µ-CT image. Because the SEM images are segmented and have a higher resolution than the µ-CT image, this algorithm integrates the super-resolution and segmentation processes. The input data are low-resolution µ-CT images, and the output data are high-resolution segmented porous structures. The experimental results show that the proposed method can achieve state-of-the-art performance.
ISSN:1874-8961
1874-8953
DOI:10.1007/s11004-018-9743-0