Cylindrical cryogenic calorimeter testing of six types of multilayer insulation systems

•Minimizing the heat load to the cryogenic system is the goal.•Determining the optimum MLI system depends on a combination of factors.•Heat flux (q), effective thermal conductivity (ke) data for 26 MLI systems.•Analysis for number of layers, layer density, and comparison to thermal models.•The Kagan...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Cryogenics (Guildford) 2018-01, Vol.89, p.58-75
Hauptverfasser: Fesmire, J.E., Johnson, W.L.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:•Minimizing the heat load to the cryogenic system is the goal.•Determining the optimum MLI system depends on a combination of factors.•Heat flux (q), effective thermal conductivity (ke) data for 26 MLI systems.•Analysis for number of layers, layer density, and comparison to thermal models.•The Kaganer k-line, a composite of 26 MLI systems, a benchmark curve of ke.•The Augustynowicz q-Band, a benchmark curve of mean heat flux for 13 MLI systems. Extensive cryogenic thermal testing of more than 100 different multilayer insulation (MLI) specimens was performed over the last 20 years for the research and development of evacuated reflective thermal insulation systems. From this data library, 26 MLI systems plus several vacuum-only systems are selected for analysis and comparison. The test apparatus, methods, and results enabled the adoption of two new technical consensus standards under ASTM International. Materials tested include reflectors of aluminum foil or double-aluminized Mylar and spacers of fiberglass paper, polyester netting, silk netting, polyester fabric, or discrete polymer standoffs. The six types of MLI systems tested are listed as follows: Mylar/Paper, Foil/Paper, Mylar/Net, Mylar/Blanket, Mylar/Fabric, Mylar/Discrete. Also tested are vacuum-only systems with different cold surface materials/finishes including stainless steel, black, copper, and aluminum. Testing was performed between the boundary temperatures of 78 K and 293 K (and up to 350 K) using a thermally guarded one-meter-long cylindrical calorimeter (Cryostat-100) for absolute heat flow measurement. Cold vacuum pressures include the full range from 1 × 10−6 torr to 760 torr with nitrogen as the residual gas. System variations include number of layers from one to 80 layers, layer densities from 0.5 to 5 layers per millimeter, and installation techniques such layer-by-layer, blankets (multi-layer assemblies), sub-blankets, seaming, butt-joining, spiral wrapping, and roll-wrapping. Experimental thermal performance data for the different MLI systems are presented in terms of heat flux and effective thermal conductivity. Benchmark cryogenic-vacuum thermal performance curves for MLI are given for comparison with different insulation approaches for storage and transfer equipment, cryostats, launch vehicles, spacecraft, or science instruments.
ISSN:0011-2275
1879-2235
DOI:10.1016/j.cryogenics.2017.11.004