Evaluation of geothermal heating from abandoned oil wells
With continuous petroleum exploitation, more and more oil wells have been abandoned, which contain abundant geothermal energy. For utilizing the geothermal energy, this paper presents a new geothermal heating system using abandoned oil wells (AOW), and a comprehensive model combing wellbore heat tra...
Gespeichert in:
Veröffentlicht in: | Energy (Oxford) 2018-01, Vol.142, p.592-607 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | With continuous petroleum exploitation, more and more oil wells have been abandoned, which contain abundant geothermal energy. For utilizing the geothermal energy, this paper presents a new geothermal heating system using abandoned oil wells (AOW), and a comprehensive model combing wellbore heat transfer, formation and building energy transport is built, parameters including geothermal production, room temperature and fluid production temperature are examined by the built model. Simultaneously, a formation temperature return model was developed to investigate the formation rewarming after heating period. Furthermore, the economic and energy analysis were performed to assessment the thermo-economic performance of the presented system. Particularly, an existing AOW with depth of 3000 m was concerned to heat a virtual building with heating area of 10000 m2. The results showed that the AOW could keep the building at around 26°C with water flow rate 20 m3/h, and the maximum heating area could reach 11000 m2. Also, the bottom-hole temperature could return to a steady point after the 2nd year. The total geothermal energy production was 5.5 × 1012J during heating period, which could reducing CO2 emission about 457 ton each year. Specially, the largest total annualized cost of the new heating system was about half of that of conventional heating system.
•An novel geothermal heating system using abandoned oil well was presented.•A existing abandoned well with depth of 3000 m could sustain 11000 m2 heating area.•The existing well could keep a building with 10000 m2 heating area at about 26 °C.•The maximum cost of the novel system is about half of that of conventional systems.•Energy production by the system is 5.4 × 1012J reducing CO2 emission about 678 ton. |
---|---|
ISSN: | 0360-5442 1873-6785 |
DOI: | 10.1016/j.energy.2017.10.062 |