A Pelvic Meckel Diverticulum Mimicking the Urinary Bladder on a Meckel Scan

To prevent misleading imaging results, it is essential to attend to quality control and technical issues. An important technical parameter is selection of a zoom factor that is appropriate for the dimensions of the camera’s field of view and of the patient’s body. Here, we present the case of an aty...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of nuclear medicine technology 2018-03, Vol.46 (1), p.65-66
Hauptverfasser: Qutbi, Mohsen, Asli, Isa Neshandar
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:To prevent misleading imaging results, it is essential to attend to quality control and technical issues. An important technical parameter is selection of a zoom factor that is appropriate for the dimensions of the camera’s field of view and of the patient’s body. Here, we present the case of an atypically located Meckel diverticulum that, because of technical issues, mimicked the urinary bladder on a Meckel scan.
ISSN:0091-4916
1535-5675
DOI:10.2967/jnmt.117.198531