Characterization of fiber radiation dosimeters with different embedded scintillator materials for radiotherapy applications

•An embedded structure X-ray optical fiber dosimeter is presented to monitor real time absorbed dose in-vivo.•We identified five kinds of scintillator materials to select the optimum one for the dosimeter.•Every scintillator material has their own emission spectra and characteristics when exposed to...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Sensors and actuators. A. Physical. 2018-01, Vol.269, p.188-195
Hauptverfasser: Hu, Yaosheng, Qin, Zhuang, Ma, Yu, Zhao, Wenhui, Sun, Weimin, Zhang, Daxin, Chen, Ziyin, Wang, Boran, Tian, He, Lewis, Elfed
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:•An embedded structure X-ray optical fiber dosimeter is presented to monitor real time absorbed dose in-vivo.•We identified five kinds of scintillator materials to select the optimum one for the dosimeter.•Every scintillator material has their own emission spectra and characteristics when exposed to X-rays.•Gd2O2S:Tb is the optimum choice of material for the X-ray optical fiber dosimeter. In-vivo real-time dose rate measurement has attracted much attention in the tumour-treatment field because of the demand for precise delivery of radiotherapy. An optical fiber based dosimeter is presented, which is fabricated by embedding scintillator materials inside the fiber core. Five micron-scale powder based scintillator materials have been identified and their characteristics are compared in this investigation. The dosimeters have been fabricated separately but with exactly the same production process. Their emission spectra have been measured. Furthermore, an evaluation of the dosimeter’s performance has been made by analyzing the signal intensity emitted from the scintillation material following transmission through a 25m length of plastic optical fiber (POF) to a distal MPPC (multi-pixel photon counter) detector. The excellent linearity of the relationship of the signal intensity and the dose rate has been established and simultaneously measured using an ionization chamber (IC) to ensure efficacy of the results. The dependence of the resulting fluorescence signal on water depth of two materials was also obtained and compared with the IC. The investigation clearly shows that currently Gd2O2S:Tb is the optimum choice of material for the X-ray optical fiber dosimeter.
ISSN:0924-4247
1873-3069
DOI:10.1016/j.sna.2017.11.014