Upper arm polytetrafluoroethylene grafts for dialysis access. Analysis of two different graft sizes: 6mm and 6-8 mm

The purpose of this retrospective study was to analyze 2 sizes of expanded polytetrafluoroethylene (PTFE) upper arm grafts for dialysis: 8 millimeters, tapered to 6 mm at the arterial side, and 6 millimeters. All upper arm PTFE grafts (Gore-Tex(R)) were performed between January 1981 and April 1997....

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Vascular and endovascular surgery 2003-09, Vol.37 (5), p.335
Hauptverfasser: Garcia-Pajares, Rosario, Polo, Jose R, Flores, Angel, Gonzalez-Tabares, Enrique, Solis, Juan V
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The purpose of this retrospective study was to analyze 2 sizes of expanded polytetrafluoroethylene (PTFE) upper arm grafts for dialysis: 8 millimeters, tapered to 6 mm at the arterial side, and 6 millimeters. All upper arm PTFE grafts (Gore-Tex(R)) were performed between January 1981 and April 1997. Patient characteristics, complication rate, and patency rates were compared for both kind of grafts. Five hundred and seven PTFE grafts were analyzed (183 6-mm grafts and 324 6- to 8-mm grafts). Early failure was found in 5 grafts (2.7%) in 6-mm grafts, and in 5 grafts (1.5%) in 8-mm grafts (not significant). Steal syndrome was found in 1 patient (0.5%) of the 6-mm group, and in 11 (3.4%) of the 8-mm grafts (p=0.085). The rate of late complications requiring surgical repair was 0.56 episode per graft-year in the 6-mm grafts group, and 0.33 in the 8-mm grafts (p
ISSN:1538-5744
1938-9116