Prebreakdown Currents in a Sealed-off Two-Section Cold-Cathode Thyratron and Methods for Increasing the Breakdown Voltage
The data on the measured static breakdown voltages and pre-breakdown currents flowing in the main gap of a two-section, sealed-off thyratron with a cold-cathode TPI1-10k/50 are presented. It is shown that pre-breakdown current in the lower section appears at lower voltages than in the upper section....
Gespeichert in:
Veröffentlicht in: | Russian physics journal 2017-12, Vol.60 (8), p.1269-1276 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The data on the measured static breakdown voltages and pre-breakdown currents flowing in the main gap of a two-section, sealed-off thyratron with a cold-cathode TPI1-10k/50 are presented. It is shown that pre-breakdown current in the lower section appears at lower voltages than in the upper section. A few methods are proposed for increasing the thyratron breakdown voltage via re-distribution of the voltage between the sections using capacitive and resistive voltage dividers. It is demonstrated that either the self-capacitance of one of the sections or the resistance due to the pre-breakdown current flow could serve as one of the arms of the divider. |
---|---|
ISSN: | 1064-8887 1573-9228 |
DOI: | 10.1007/s11182-017-1207-3 |