Ultra-light weight undamped tuned dynamic absorber for cryogenically cooled infrared electro-optic payload
•Special design of a light-weight tuned dynamic absorber featuring planar flexural bearings and frictionless anchoring features resulted in achieving exceptionally low 0.013% damping ratio.•In a combination with high-resolution 0.001Hz frequency tuning, this allowed in excess of 100-fold vibration a...
Gespeichert in:
Veröffentlicht in: | Cryogenics (Guildford) 2017-04, Vol.83, p.22-30 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | •Special design of a light-weight tuned dynamic absorber featuring planar flexural bearings and frictionless anchoring features resulted in achieving exceptionally low 0.013% damping ratio.•In a combination with high-resolution 0.001Hz frequency tuning, this allowed in excess of 100-fold vibration attenuation of the vibration sensitive electro-optical infrared device by adding only 5% to the payload weight.
Attenuation of tonal cryocooler induced vibration in infrared electro-optical payloads may be achieved by using of Tuned Dynamic Absorber (TDA) which is, generally speaking, a passive, weakly damped mass-spring system the resonant frequency of which is precisely matched with the driving frequency.
Added TDA results in a favorable modification of the frequency response functions of combined structure. In particular, a favorable antiresonant notch appears at the frequency of tonal excitation along with the adjacent secondary resonance, the width and depth of which along with its closeness to the secondary resonance are strongly dependent on the mass and damping ratios. Using heavier TDA favorably results in wider and deeper antiresonant notch along with increased gap between antiresonant and resonant frequencies. Lowering damping in TDA favorably results in deepening the antiresonant notch.
The weight of TDA is usually subjected to tight design constrains. Use of lightweight TDA not only diminishes the attainable performance but also complicates the procedure of frequency matching. Along these lines, even minor frequency deviations may negate the TDA performance and even result in TDA failure in case of resonant build up.
The authors are presenting theoretical and practical aspects of designing and constructing ultra-light weight TDA in application to vibration attenuation of electro-optical infrared payload relying on Split Stirling linear cryocooler, the driving frequency of which is fixed and may be accurately tuned and maintained using a digital controller over the entire range of working conditions and lifetime; the lack of mass ratio is compensated by minimizing the damping ratio. In one particular case, in excess of 100-fold vibration attenuation has been achieved by adding as little as 5% to the payload weight. |
---|---|
ISSN: | 0011-2275 1879-2235 |
DOI: | 10.1016/j.cryogenics.2017.01.008 |