Transient Thermal Stress Analysis of BOF Hood Failure

The failure of BOF hood tube is a common industrial problem that has received little attention in literature. The major mode of failure as observed by most of the industries is thermal fatigue failure. Earlier people have studied the thermal stress profile in hood system considering constant water t...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of failure analysis and prevention 2017-06, Vol.17 (3), p.496-504
Hauptverfasser: Das, P. K., Sarkar, S., Ajmani, S. K.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The failure of BOF hood tube is a common industrial problem that has received little attention in literature. The major mode of failure as observed by most of the industries is thermal fatigue failure. Earlier people have studied the thermal stress profile in hood system considering constant water temperature. However, in reality there are fluctuations in water temperature due to cyclic thermal load caused by BOF gas. Present study reveals that the water temperature fluctuation is having significant impact in causing thermal fatigue failure. The change in water velocity and tube thickness has negligible effect in thermal fatigue failure compared to that observed for water temperature fluctuation. However, tube material of construction is also having significant impact on its failure.
ISSN:1547-7029
1728-5674
1864-1245
DOI:10.1007/s11668-017-0267-6