Determination of isotopic composition of uranium samples using alpha spectrometry

Alpha spectrometry has been employed for the determination of the atom ratios of low enriched uranium samples. WinALPHA was used for the deconvolution and tail correction of the alpha spectra. The atom ratios calculated from alpha spectrometry were compared with that obtained by thermal ionisation m...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of radioanalytical and nuclear chemistry 2016-11, Vol.310 (2), p.541-546
Hauptverfasser: Alamelu, D., Jagadish Kumar, S.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Alpha spectrometry has been employed for the determination of the atom ratios of low enriched uranium samples. WinALPHA was used for the deconvolution and tail correction of the alpha spectra. The atom ratios calculated from alpha spectrometry were compared with that obtained by thermal ionisation mass spectrometry. The results are in good agreement and is encouraging. The tail correction methodology WinALPHA is shown to be applicable for deconvoluting when the alpha activity of high energy peak is more than 45 times the lower energy peaks for obtaining the correct alpha activity ratio which is very challenging and been done for the first time.
ISSN:0236-5731
1588-2780
DOI:10.1007/s10967-016-4874-6