Headspace gas-chromatographic determination of formaldehyde in urine

A method is proposed for determining formaldehyde by headspace gas chromatography using an o -(2,3,4,5,6-pentafluorobenzyl)hydroxylamine (PFBHA) derivatizing agent. Formaldehyde in urine was derivatized to o -(pentafluorobenzyl)oxime and extracted by heating an urine sample with PFBHA in a sealed vi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of analytical chemistry (New York, N.Y.) N.Y.), 2017, Vol.72 (1), p.83-86
Hauptverfasser: Alekseenko, A. N., Zhurba, O. M., Efimova, N. V., Rukavishnikov, V. S.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A method is proposed for determining formaldehyde by headspace gas chromatography using an o -(2,3,4,5,6-pentafluorobenzyl)hydroxylamine (PFBHA) derivatizing agent. Formaldehyde in urine was derivatized to o -(pentafluorobenzyl)oxime and extracted by heating an urine sample with PFBHA in a sealed vial. Gas-chromatographic analysis of the headspace was performed in the temperature-programmed mode using an HP-5 capillary column with a flame ionization detector. The limit of detection is 3.5 μg/L. The accuracy of the procedure, equivalent to an extended relative uncertainty, does not exceed 21%. The examination of the procedure using urine samples of the population of the Irkutsk region has shown that the regional reference levels of formaldehyde concentration are in the range 44–83 μg/L.
ISSN:1061-9348
1608-3199
DOI:10.1134/S1061934816110022