Simultaneous Determination and Drug Dissolution Testing of Combined Amlodipine Tablet Formulations Using RP-LC

In the proposed work, the simultaneous analysis of amlodipine–rosuvastatin and amlodipine–atorvastatin in their dosage forms was achieved. Simultaneous dissolution profiles of the amlodipine–rosuvastatin and amlodipine–atorvastatin tablets are realized using Apparatus II with a simple, accurate and...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Chromatographia 2016-09, Vol.79 (17-18), p.1143-1151
Hauptverfasser: Ozkan, Cansel Kose, Kurbanoglu, Sevinc, Esim, Ozgur, Savaser, Ayhan, Ozkan, Sibel A., Ozkan, Yalcin
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In the proposed work, the simultaneous analysis of amlodipine–rosuvastatin and amlodipine–atorvastatin in their dosage forms was achieved. Simultaneous dissolution profiles of the amlodipine–rosuvastatin and amlodipine–atorvastatin tablets are realized using Apparatus II with a simple, accurate and precise RP-LC method. The mobile phase consisting of 0.2 % H 3 PO 4 and pH 5:methanol:acetonitrile (46:27:27) was used. The samples of 10 µL were injected onto a Zorbax SB C18 (100 mm, 4.6 mm, 3.5 µm particle size) column with 1.2 µL min −1 flow rate. The samples were detected at 236 nm. By plotting peak area ratios vs. concentration, the linearity for amlodipine–rosuvastatin and amlodipine–atorvastatin was determined. With the developed RP-LC method, AML, ROS and ATOR were detected within the range of 0.25–10, 0.5–10 and 0.25–25 µg mL −1 , respectively. LOD and LOQ values were also calculated as 0.028, 0.058, 0.021 and 0.095 µg mL −1 , 0.195 µg mL −1 , 0.070 µg mL −1 for AML, ROS and ATOR, respectively. System suitability tests parameters, such as capacity factor, selectivity to previous peak, selectivity to next peak, resolution to previous peak, resolution to next peak, tailing factor, theoretical number of plates, were performed and found coherent with the ICH guideline parameters. The proposed method has been extensively validated in terms of recovery, and recovery results were between 99 and 101 %. For proving the precision, between-day and within-day repeatability results of the method were proposed. The method can be used for the simultaneous determination of amlodipine–rosuvastatin and amlodipine–atorvastatin.
ISSN:0009-5893
1612-1112
DOI:10.1007/s10337-016-3125-x