Electrocatalytic performance of cobalt microparticles film-modified platinum disk electrode for amperometric detection of ascorbic acid
Deposited cobalt microparticales ( Co-MPs ) film onto the platinum disk electrode has been successfully used as a new amperometric sensor for the determination of ascorbic acid ( AA ). AA is detected by surface catalyzed oxidation involving cobalt(III) oxyhydroxides in alkaline solution. The Co-MPs/...
Gespeichert in:
Veröffentlicht in: | Journal of analytical chemistry (New York, N.Y.) N.Y.), 2017-03, Vol.72 (3), p.333-341 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Deposited cobalt microparticales (
Co-MPs
) film onto the platinum disk electrode has been successfully used as a new amperometric sensor for the determination of ascorbic acid (
AA
). AA is detected by surface catalyzed oxidation involving cobalt(III) oxyhydroxides in alkaline solution. The Co-MPs/Pt electrode exhibits a high electrocatalytic activity toward the AA oxidation. The diffusion coefficient of AA (6.09 × 10
5
cm
2
/s) and the catalytic rate constant (
k
cat
= 6.27 × 10
3
M
–1
s
–1
) have been determined using electrochemical approaches. The amperometric response of the modified electrode is linear against the AA concentration in the range (0.01‒0.48 mM). The sensor displays the best activity with a high response signal, a good sensitivity of 74.3 μA/mM, a low detection limit of 2.5 μM (signal/noise = 3) and a fast response time ( |
---|---|
ISSN: | 1061-9348 1608-3199 |
DOI: | 10.1134/S106193481703008X |