Simple flow injection analysis system for determination of added sugars in dairy products
A microbial sensor based on a carbon dioxide electrode coupled with immobilized Saccharomyces cerevisiae (baker's yeast) has been used for the determination of sucrose in dairy products. The sensor was used as the detector in a flow injection analysis system. Calibration curves for sucrose were...
Gespeichert in:
Veröffentlicht in: | Journal of dairy research 1998-11, Vol.65 (4), p.675-680 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 680 |
---|---|
container_issue | 4 |
container_start_page | 675 |
container_title | Journal of dairy research |
container_volume | 65 |
creator | CORTÓN, EDUARDO LOCASCIO, GUILLERMO |
description | A microbial sensor based on a carbon dioxide electrode coupled
with
immobilized Saccharomyces cerevisiae (baker's yeast) has
been used for the
determination of sucrose in dairy products. The sensor was used as the
detector in a
flow injection analysis system. Calibration curves for sucrose were established
from
1 to 100 g/l. Determinations for several dairy products containing
added sucrose
gave good agreement with the concentrations given by manufacturers. Typically,
the
se of the method was shown to be |
doi_str_mv | 10.1017/S0022029998003045 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_1840048703</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><cupid>10_1017_S0022029998003045</cupid><sourcerecordid>1840048703</sourcerecordid><originalsourceid>FETCH-LOGICAL-c382t-aaad65d63f8b7fffd588691aec254b7c060679c9df151ac5c5cb28f96beb3a33</originalsourceid><addsrcrecordid>eNp1kN1LHDEUxUOx0NX6B_QtYF9HbyYzmeRRFl0Lglql0qdwJx-S7XysySx1__tmu0sriNyH-3B-597DIeQLg1MGrDm7ByhLKJVSEoBDVX8gM1YJVTSiVAdktpWLrf6JHKa0BGAclJiRn_ehX3WO-m78TcOwdGYK40BxwG6TQqJpkybXUz9Gat3kYh8G_EuMnqK1ztK0fsKYspdaDHFDV3G0azOlz-Sjxy654_0-Ig-XFw_zq-L6ZvFtfn5dGC7LqUBEK2oruJdt4723tZRCMXSmrKu2MSBANMoo61nN0NR52lJ6JVrXcuT8iJzszua_z2uXJr0c1zHHT5rJCqCSDWwptqNMHFOKzutVDD3GjWagtwXqNwVmz9f9ZUwGOx9xMCH9N9YyU5CxYoeF3NTLPxnjLy0a3tRaLO4yfPtj_v1O6sfM830U7NsY7JN7lfjdMH8Aps6PdQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1840048703</pqid></control><display><type>article</type><title>Simple flow injection analysis system for determination of added sugars in dairy products</title><source>Cambridge Journals</source><source>Periodicals Index Online</source><creator>CORTÓN, EDUARDO ; LOCASCIO, GUILLERMO</creator><creatorcontrib>CORTÓN, EDUARDO ; LOCASCIO, GUILLERMO</creatorcontrib><description>A microbial sensor based on a carbon dioxide electrode coupled
with
immobilized Saccharomyces cerevisiae (baker's yeast) has
been used for the
determination of sucrose in dairy products. The sensor was used as the
detector in a
flow injection analysis system. Calibration curves for sucrose were established
from
1 to 100 g/l. Determinations for several dairy products containing
added sucrose
gave good agreement with the concentrations given by manufacturers. Typically,
the
se of the method was shown to be <5% of the calculated mean.</description><identifier>ISSN: 0022-0299</identifier><identifier>EISSN: 1469-7629</identifier><identifier>DOI: 10.1017/S0022029998003045</identifier><identifier>CODEN: JDRSAN</identifier><language>eng</language><publisher>Cambridge: Cambridge University Press</publisher><subject>Biological and medical sciences ; Food industries ; Fundamental and applied biological sciences. Psychology ; Milk and cheese industries. Ice creams</subject><ispartof>Journal of dairy research, 1998-11, Vol.65 (4), p.675-680</ispartof><rights>Proprietors of Journal of Dairy Research 1998</rights><rights>1999 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c382t-aaad65d63f8b7fffd588691aec254b7c060679c9df151ac5c5cb28f96beb3a33</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.cambridge.org/core/product/identifier/S0022029998003045/type/journal_article$$EHTML$$P50$$Gcambridge$$H</linktohtml><link.rule.ids>164,314,780,784,27869,27924,27925,55628</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=1580450$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>CORTÓN, EDUARDO</creatorcontrib><creatorcontrib>LOCASCIO, GUILLERMO</creatorcontrib><title>Simple flow injection analysis system for determination of added sugars in dairy products</title><title>Journal of dairy research</title><addtitle>Journal of Dairy Research</addtitle><description>A microbial sensor based on a carbon dioxide electrode coupled
with
immobilized Saccharomyces cerevisiae (baker's yeast) has
been used for the
determination of sucrose in dairy products. The sensor was used as the
detector in a
flow injection analysis system. Calibration curves for sucrose were established
from
1 to 100 g/l. Determinations for several dairy products containing
added sucrose
gave good agreement with the concentrations given by manufacturers. Typically,
the
se of the method was shown to be <5% of the calculated mean.</description><subject>Biological and medical sciences</subject><subject>Food industries</subject><subject>Fundamental and applied biological sciences. Psychology</subject><subject>Milk and cheese industries. Ice creams</subject><issn>0022-0299</issn><issn>1469-7629</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1998</creationdate><recordtype>article</recordtype><sourceid>K30</sourceid><recordid>eNp1kN1LHDEUxUOx0NX6B_QtYF9HbyYzmeRRFl0Lglql0qdwJx-S7XysySx1__tmu0sriNyH-3B-597DIeQLg1MGrDm7ByhLKJVSEoBDVX8gM1YJVTSiVAdktpWLrf6JHKa0BGAclJiRn_ehX3WO-m78TcOwdGYK40BxwG6TQqJpkybXUz9Gat3kYh8G_EuMnqK1ztK0fsKYspdaDHFDV3G0azOlz-Sjxy654_0-Ig-XFw_zq-L6ZvFtfn5dGC7LqUBEK2oruJdt4723tZRCMXSmrKu2MSBANMoo61nN0NR52lJ6JVrXcuT8iJzszua_z2uXJr0c1zHHT5rJCqCSDWwptqNMHFOKzutVDD3GjWagtwXqNwVmz9f9ZUwGOx9xMCH9N9YyU5CxYoeF3NTLPxnjLy0a3tRaLO4yfPtj_v1O6sfM830U7NsY7JN7lfjdMH8Aps6PdQ</recordid><startdate>19981101</startdate><enddate>19981101</enddate><creator>CORTÓN, EDUARDO</creator><creator>LOCASCIO, GUILLERMO</creator><general>Cambridge University Press</general><general>[Cambridge]:Cambridge University Press</general><scope>BSCLL</scope><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7WH</scope><scope>K30</scope><scope>PAAUG</scope><scope>PAWHS</scope><scope>PAWZZ</scope><scope>PAXOH</scope><scope>PBHAV</scope><scope>PBQSW</scope><scope>PBYQZ</scope><scope>PCIWU</scope><scope>PCMID</scope><scope>PCZJX</scope><scope>PDGRG</scope><scope>PDWWI</scope><scope>PETMR</scope><scope>PFVGT</scope><scope>PGXDX</scope><scope>PIHIL</scope><scope>PISVA</scope><scope>PJCTQ</scope><scope>PJTMS</scope><scope>PLCHJ</scope><scope>PMHAD</scope><scope>PNQDJ</scope><scope>POUND</scope><scope>PPLAD</scope><scope>PQAPC</scope><scope>PQCAN</scope><scope>PQCMW</scope><scope>PQEME</scope><scope>PQHKH</scope><scope>PQMID</scope><scope>PQNCT</scope><scope>PQNET</scope><scope>PQSCT</scope><scope>PQSET</scope><scope>PSVJG</scope><scope>PVMQY</scope><scope>PZGFC</scope></search><sort><creationdate>19981101</creationdate><title>Simple flow injection analysis system for determination of added sugars in dairy products</title><author>CORTÓN, EDUARDO ; LOCASCIO, GUILLERMO</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c382t-aaad65d63f8b7fffd588691aec254b7c060679c9df151ac5c5cb28f96beb3a33</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1998</creationdate><topic>Biological and medical sciences</topic><topic>Food industries</topic><topic>Fundamental and applied biological sciences. Psychology</topic><topic>Milk and cheese industries. Ice creams</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>CORTÓN, EDUARDO</creatorcontrib><creatorcontrib>LOCASCIO, GUILLERMO</creatorcontrib><collection>Istex</collection><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Periodicals Index Online Segment 50</collection><collection>Periodicals Index Online</collection><collection>Primary Sources Access—Foundation Edition (Plan E) - West</collection><collection>Primary Sources Access (Plan D) - International</collection><collection>Primary Sources Access & Build (Plan A) - MEA</collection><collection>Primary Sources Access—Foundation Edition (Plan E) - Midwest</collection><collection>Primary Sources Access—Foundation Edition (Plan E) - Northeast</collection><collection>Primary Sources Access (Plan D) - Southeast</collection><collection>Primary Sources Access (Plan D) - North Central</collection><collection>Primary Sources Access—Foundation Edition (Plan E) - Southeast</collection><collection>Primary Sources Access (Plan D) - South Central</collection><collection>Primary Sources Access & Build (Plan A) - UK / I</collection><collection>Primary Sources Access (Plan D) - Canada</collection><collection>Primary Sources Access (Plan D) - EMEALA</collection><collection>Primary Sources Access—Foundation Edition (Plan E) - North Central</collection><collection>Primary Sources Access—Foundation Edition (Plan E) - South Central</collection><collection>Primary Sources Access & Build (Plan A) - International</collection><collection>Primary Sources Access—Foundation Edition (Plan E) - International</collection><collection>Primary Sources Access (Plan D) - West</collection><collection>Periodicals Index Online Segments 1-50</collection><collection>Primary Sources Access (Plan D) - APAC</collection><collection>Primary Sources Access (Plan D) - Midwest</collection><collection>Primary Sources Access (Plan D) - MEA</collection><collection>Primary Sources Access—Foundation Edition (Plan E) - Canada</collection><collection>Primary Sources Access—Foundation Edition (Plan E) - UK / I</collection><collection>Primary Sources Access—Foundation Edition (Plan E) - EMEALA</collection><collection>Primary Sources Access & Build (Plan A) - APAC</collection><collection>Primary Sources Access & Build (Plan A) - Canada</collection><collection>Primary Sources Access & Build (Plan A) - West</collection><collection>Primary Sources Access & Build (Plan A) - EMEALA</collection><collection>Primary Sources Access (Plan D) - Northeast</collection><collection>Primary Sources Access & Build (Plan A) - Midwest</collection><collection>Primary Sources Access & Build (Plan A) - North Central</collection><collection>Primary Sources Access & Build (Plan A) - Northeast</collection><collection>Primary Sources Access & Build (Plan A) - South Central</collection><collection>Primary Sources Access & Build (Plan A) - Southeast</collection><collection>Primary Sources Access (Plan D) - UK / I</collection><collection>Primary Sources Access—Foundation Edition (Plan E) - APAC</collection><collection>Primary Sources Access—Foundation Edition (Plan E) - MEA</collection><jtitle>Journal of dairy research</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>CORTÓN, EDUARDO</au><au>LOCASCIO, GUILLERMO</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Simple flow injection analysis system for determination of added sugars in dairy products</atitle><jtitle>Journal of dairy research</jtitle><addtitle>Journal of Dairy Research</addtitle><date>1998-11-01</date><risdate>1998</risdate><volume>65</volume><issue>4</issue><spage>675</spage><epage>680</epage><pages>675-680</pages><issn>0022-0299</issn><eissn>1469-7629</eissn><coden>JDRSAN</coden><abstract>A microbial sensor based on a carbon dioxide electrode coupled
with
immobilized Saccharomyces cerevisiae (baker's yeast) has
been used for the
determination of sucrose in dairy products. The sensor was used as the
detector in a
flow injection analysis system. Calibration curves for sucrose were established
from
1 to 100 g/l. Determinations for several dairy products containing
added sucrose
gave good agreement with the concentrations given by manufacturers. Typically,
the
se of the method was shown to be <5% of the calculated mean.</abstract><cop>Cambridge</cop><pub>Cambridge University Press</pub><doi>10.1017/S0022029998003045</doi><tpages>6</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0022-0299 |
ispartof | Journal of dairy research, 1998-11, Vol.65 (4), p.675-680 |
issn | 0022-0299 1469-7629 |
language | eng |
recordid | cdi_proquest_journals_1840048703 |
source | Cambridge Journals; Periodicals Index Online |
subjects | Biological and medical sciences Food industries Fundamental and applied biological sciences. Psychology Milk and cheese industries. Ice creams |
title | Simple flow injection analysis system for determination of added sugars in dairy products |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T11%3A53%3A22IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Simple%20flow%20injection%20analysis%20system%20for%20determination%20of%20added%20sugars%20in%20dairy%20products&rft.jtitle=Journal%20of%20dairy%20research&rft.au=CORT%C3%93N,%20EDUARDO&rft.date=1998-11-01&rft.volume=65&rft.issue=4&rft.spage=675&rft.epage=680&rft.pages=675-680&rft.issn=0022-0299&rft.eissn=1469-7629&rft.coden=JDRSAN&rft_id=info:doi/10.1017/S0022029998003045&rft_dat=%3Cproquest_cross%3E1840048703%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1840048703&rft_id=info:pmid/&rft_cupid=10_1017_S0022029998003045&rfr_iscdi=true |