呼吸同期放射線治療の改良に向けた内臓変位の解析

We have analyzed a displacement of lung tissues induced by aspiration and expressed it by a phenomenologically derived ellipsoidal harmonics for time course of craniocaudal displacement for a cycle of aspiration. A fitting of the equation to 4DCT images for a pair of lung of five individuals was use...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Nihon Reoroji Gakkaishi 2016/10/15, Vol.44(4), pp.195-204
Hauptverfasser: 樋口, 雅則, 山本, 隆夫, 岡村, 英希, 太田, 直哉, 槇, 靖幸, 江原, 威, 土橋, 敏明
Format: Artikel
Sprache:jpn
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:We have analyzed a displacement of lung tissues induced by aspiration and expressed it by a phenomenologically derived ellipsoidal harmonics for time course of craniocaudal displacement for a cycle of aspiration. A fitting of the equation to 4DCT images for a pair of lung of five individuals was used for the analysis of the displacement. The observed data were fitted well to the phenomenological equation. The positional dependence of the fitting parameters was reasonably explained. It is suggested that the parameter that denotes the width of the expiration phase could be used to evaluate the validation of the respiratory-gated imaging technique in irradiation therapy for each patient.
ISSN:0387-1533
2186-4586
DOI:10.1678/rheology.44.195