APMP.T-K3.4: key comparison of realizations of the ITS-90 over the range -38.8344 °C to 419.527 °C
The APMP bilateral key comparison APMP.T-K3.4 was initiated on the request from RCM-LIPI (Indonesia) to link their national standards to the average reference values (ARVs) of the CCT-K3. Korea Research Institute of Standards and Science (KRISS, Republic of Korea) provided the linkage to the CCT-K3...
Gespeichert in:
Veröffentlicht in: | Metrologia 2016-01, Vol.53 (1A), p.3006 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | 1A |
container_start_page | 3006 |
container_title | Metrologia |
container_volume | 53 |
creator | Joung, W Gam, K S Achmadi, A Trisna, B A |
description | The APMP bilateral key comparison APMP.T-K3.4 was initiated on the request from RCM-LIPI (Indonesia) to link their national standards to the average reference values (ARVs) of the CCT-K3. Korea Research Institute of Standards and Science (KRISS, Republic of Korea) provided the linkage to the CCT-K3 for temperatures ranging from -38.8344 °C to 419.527 °C. In the APMP.T-K3.4, two standard platinum resistance thermometers (SPRTs) were chosen as the transfer instruments and were calibrated at the ITS-90 fixed-points in the comparison range. The fixed-points in this comparison included Zn freezing point (419.527 °C), Sn freezing point (231.928 °C), In freezing point (156.5985 °C), Ga melting point (29.7646 °C), and Hg triple point (-38.8344 °C). The comparison was carried out in a participant-pilot-participant sequence where KRISS served as the pilot. The linkage was based on the fixed-point resistance ratios of RCM-LIPI relative to the ARVs of the CCT-K3 via the difference between the fixed-point resistance ratios of KRISS and the ARVs of the CCT-K3. The temperature differences between the national standards of RCM-LIPI and the ARVs of the CCT-K3 were within the evaluated comparison uncertainties of the ATPM.T-K3.4. This report provides detailed information on the comparison results, linkage mechanism, and the Degree of Equivalence of the RCM-LIPI relative to the institutes having participated in the CCT-K3.
Main text
To reach the main text of this paper, click on
Final Report
. Note that this text is that which appears in Appendix B of the BIPM key comparison database
kcdb.bipm.org/
.
The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA). |
doi_str_mv | 10.1088/0026-1394/53/1A/03006 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_1829751662</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>4218105301</sourcerecordid><originalsourceid>FETCH-LOGICAL-c249t-a5735562be465d273fe49da43f20ac68ccfe2c4090677faa8a4a88bceaf2d9a03</originalsourceid><addsrcrecordid>eNo9kN1KwzAYhoMoOKeXIAQ8Tpv_pJ6V4c9w4sB5HLI01c6tmUknzKvyGrwy1008-njg4f3gAeCS4IxgrXOMqUSEFTwXLCdljhnG8ggMiNQEKaHEMRj8O6fgLKUFxkRRoQagKqeP02yGHljGr-G730IXVmsbmxRaGGoYvV02X7ZrQpt67t48HM-eUYFh-PRxz9G2rx4ipjPNOIc_3yPYBchJkQmqejwHJ7VdJn_xd4fg5fZmNrpHk6e78aicIEd50SErFBNC0rnnUlRUsdrzorKc1RRbJ7VztaeO4wJLpWprteVW67nztqZVYTEbgqvD7jqGj41PnVmETWx3Lw3RtFCCSEl3ljhYLoaUoq_NOjYrG7eGYNMHNX0s08cyghlSmn1Q9gtUrWUp</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1829751662</pqid></control><display><type>article</type><title>APMP.T-K3.4: key comparison of realizations of the ITS-90 over the range -38.8344 °C to 419.527 °C</title><source>Institute of Physics Journals</source><creator>Joung, W ; Gam, K S ; Achmadi, A ; Trisna, B A</creator><creatorcontrib>Joung, W ; Gam, K S ; Achmadi, A ; Trisna, B A</creatorcontrib><description>The APMP bilateral key comparison APMP.T-K3.4 was initiated on the request from RCM-LIPI (Indonesia) to link their national standards to the average reference values (ARVs) of the CCT-K3. Korea Research Institute of Standards and Science (KRISS, Republic of Korea) provided the linkage to the CCT-K3 for temperatures ranging from -38.8344 °C to 419.527 °C. In the APMP.T-K3.4, two standard platinum resistance thermometers (SPRTs) were chosen as the transfer instruments and were calibrated at the ITS-90 fixed-points in the comparison range. The fixed-points in this comparison included Zn freezing point (419.527 °C), Sn freezing point (231.928 °C), In freezing point (156.5985 °C), Ga melting point (29.7646 °C), and Hg triple point (-38.8344 °C). The comparison was carried out in a participant-pilot-participant sequence where KRISS served as the pilot. The linkage was based on the fixed-point resistance ratios of RCM-LIPI relative to the ARVs of the CCT-K3 via the difference between the fixed-point resistance ratios of KRISS and the ARVs of the CCT-K3. The temperature differences between the national standards of RCM-LIPI and the ARVs of the CCT-K3 were within the evaluated comparison uncertainties of the ATPM.T-K3.4. This report provides detailed information on the comparison results, linkage mechanism, and the Degree of Equivalence of the RCM-LIPI relative to the institutes having participated in the CCT-K3.
Main text
To reach the main text of this paper, click on
Final Report
. Note that this text is that which appears in Appendix B of the BIPM key comparison database
kcdb.bipm.org/
.
The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).</description><identifier>ISSN: 0026-1394</identifier><identifier>EISSN: 1681-7575</identifier><identifier>DOI: 10.1088/0026-1394/53/1A/03006</identifier><language>eng</language><publisher>Bristol: IOP Publishing</publisher><subject>Comparative analysis ; Freezing ; Platinum ; Resistance thermometers ; Uncertainty</subject><ispartof>Metrologia, 2016-01, Vol.53 (1A), p.3006</ispartof><rights>Copyright IOP Publishing 2016</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c249t-a5735562be465d273fe49da43f20ac68ccfe2c4090677faa8a4a88bceaf2d9a03</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Joung, W</creatorcontrib><creatorcontrib>Gam, K S</creatorcontrib><creatorcontrib>Achmadi, A</creatorcontrib><creatorcontrib>Trisna, B A</creatorcontrib><title>APMP.T-K3.4: key comparison of realizations of the ITS-90 over the range -38.8344 °C to 419.527 °C</title><title>Metrologia</title><description>The APMP bilateral key comparison APMP.T-K3.4 was initiated on the request from RCM-LIPI (Indonesia) to link their national standards to the average reference values (ARVs) of the CCT-K3. Korea Research Institute of Standards and Science (KRISS, Republic of Korea) provided the linkage to the CCT-K3 for temperatures ranging from -38.8344 °C to 419.527 °C. In the APMP.T-K3.4, two standard platinum resistance thermometers (SPRTs) were chosen as the transfer instruments and were calibrated at the ITS-90 fixed-points in the comparison range. The fixed-points in this comparison included Zn freezing point (419.527 °C), Sn freezing point (231.928 °C), In freezing point (156.5985 °C), Ga melting point (29.7646 °C), and Hg triple point (-38.8344 °C). The comparison was carried out in a participant-pilot-participant sequence where KRISS served as the pilot. The linkage was based on the fixed-point resistance ratios of RCM-LIPI relative to the ARVs of the CCT-K3 via the difference between the fixed-point resistance ratios of KRISS and the ARVs of the CCT-K3. The temperature differences between the national standards of RCM-LIPI and the ARVs of the CCT-K3 were within the evaluated comparison uncertainties of the ATPM.T-K3.4. This report provides detailed information on the comparison results, linkage mechanism, and the Degree of Equivalence of the RCM-LIPI relative to the institutes having participated in the CCT-K3.
Main text
To reach the main text of this paper, click on
Final Report
. Note that this text is that which appears in Appendix B of the BIPM key comparison database
kcdb.bipm.org/
.
The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).</description><subject>Comparative analysis</subject><subject>Freezing</subject><subject>Platinum</subject><subject>Resistance thermometers</subject><subject>Uncertainty</subject><issn>0026-1394</issn><issn>1681-7575</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><recordid>eNo9kN1KwzAYhoMoOKeXIAQ8Tpv_pJ6V4c9w4sB5HLI01c6tmUknzKvyGrwy1008-njg4f3gAeCS4IxgrXOMqUSEFTwXLCdljhnG8ggMiNQEKaHEMRj8O6fgLKUFxkRRoQagKqeP02yGHljGr-G730IXVmsbmxRaGGoYvV02X7ZrQpt67t48HM-eUYFh-PRxz9G2rx4ipjPNOIc_3yPYBchJkQmqejwHJ7VdJn_xd4fg5fZmNrpHk6e78aicIEd50SErFBNC0rnnUlRUsdrzorKc1RRbJ7VztaeO4wJLpWprteVW67nztqZVYTEbgqvD7jqGj41PnVmETWx3Lw3RtFCCSEl3ljhYLoaUoq_NOjYrG7eGYNMHNX0s08cyghlSmn1Q9gtUrWUp</recordid><startdate>20160101</startdate><enddate>20160101</enddate><creator>Joung, W</creator><creator>Gam, K S</creator><creator>Achmadi, A</creator><creator>Trisna, B A</creator><general>IOP Publishing</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope></search><sort><creationdate>20160101</creationdate><title>APMP.T-K3.4: key comparison of realizations of the ITS-90 over the range -38.8344 °C to 419.527 °C</title><author>Joung, W ; Gam, K S ; Achmadi, A ; Trisna, B A</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c249t-a5735562be465d273fe49da43f20ac68ccfe2c4090677faa8a4a88bceaf2d9a03</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>Comparative analysis</topic><topic>Freezing</topic><topic>Platinum</topic><topic>Resistance thermometers</topic><topic>Uncertainty</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Joung, W</creatorcontrib><creatorcontrib>Gam, K S</creatorcontrib><creatorcontrib>Achmadi, A</creatorcontrib><creatorcontrib>Trisna, B A</creatorcontrib><collection>CrossRef</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Metrologia</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Joung, W</au><au>Gam, K S</au><au>Achmadi, A</au><au>Trisna, B A</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>APMP.T-K3.4: key comparison of realizations of the ITS-90 over the range -38.8344 °C to 419.527 °C</atitle><jtitle>Metrologia</jtitle><date>2016-01-01</date><risdate>2016</risdate><volume>53</volume><issue>1A</issue><spage>3006</spage><pages>3006-</pages><issn>0026-1394</issn><eissn>1681-7575</eissn><abstract>The APMP bilateral key comparison APMP.T-K3.4 was initiated on the request from RCM-LIPI (Indonesia) to link their national standards to the average reference values (ARVs) of the CCT-K3. Korea Research Institute of Standards and Science (KRISS, Republic of Korea) provided the linkage to the CCT-K3 for temperatures ranging from -38.8344 °C to 419.527 °C. In the APMP.T-K3.4, two standard platinum resistance thermometers (SPRTs) were chosen as the transfer instruments and were calibrated at the ITS-90 fixed-points in the comparison range. The fixed-points in this comparison included Zn freezing point (419.527 °C), Sn freezing point (231.928 °C), In freezing point (156.5985 °C), Ga melting point (29.7646 °C), and Hg triple point (-38.8344 °C). The comparison was carried out in a participant-pilot-participant sequence where KRISS served as the pilot. The linkage was based on the fixed-point resistance ratios of RCM-LIPI relative to the ARVs of the CCT-K3 via the difference between the fixed-point resistance ratios of KRISS and the ARVs of the CCT-K3. The temperature differences between the national standards of RCM-LIPI and the ARVs of the CCT-K3 were within the evaluated comparison uncertainties of the ATPM.T-K3.4. This report provides detailed information on the comparison results, linkage mechanism, and the Degree of Equivalence of the RCM-LIPI relative to the institutes having participated in the CCT-K3.
Main text
To reach the main text of this paper, click on
Final Report
. Note that this text is that which appears in Appendix B of the BIPM key comparison database
kcdb.bipm.org/
.
The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).</abstract><cop>Bristol</cop><pub>IOP Publishing</pub><doi>10.1088/0026-1394/53/1A/03006</doi></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0026-1394 |
ispartof | Metrologia, 2016-01, Vol.53 (1A), p.3006 |
issn | 0026-1394 1681-7575 |
language | eng |
recordid | cdi_proquest_journals_1829751662 |
source | Institute of Physics Journals |
subjects | Comparative analysis Freezing Platinum Resistance thermometers Uncertainty |
title | APMP.T-K3.4: key comparison of realizations of the ITS-90 over the range -38.8344 °C to 419.527 °C |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T13%3A18%3A43IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=APMP.T-K3.4:%20key%20comparison%20of%20realizations%20of%20the%20ITS-90%20over%20the%20range%20-38.8344%20%C2%B0C%20to%20419.527%20%C2%B0C&rft.jtitle=Metrologia&rft.au=Joung,%20W&rft.date=2016-01-01&rft.volume=53&rft.issue=1A&rft.spage=3006&rft.pages=3006-&rft.issn=0026-1394&rft.eissn=1681-7575&rft_id=info:doi/10.1088/0026-1394/53/1A/03006&rft_dat=%3Cproquest_cross%3E4218105301%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1829751662&rft_id=info:pmid/&rfr_iscdi=true |