APMP.T-K3.4: key comparison of realizations of the ITS-90 over the range -38.8344 °C to 419.527 °C

The APMP bilateral key comparison APMP.T-K3.4 was initiated on the request from RCM-LIPI (Indonesia) to link their national standards to the average reference values (ARVs) of the CCT-K3. Korea Research Institute of Standards and Science (KRISS, Republic of Korea) provided the linkage to the CCT-K3...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Metrologia 2016-01, Vol.53 (1A), p.3006
Hauptverfasser: Joung, W, Gam, K S, Achmadi, A, Trisna, B A
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The APMP bilateral key comparison APMP.T-K3.4 was initiated on the request from RCM-LIPI (Indonesia) to link their national standards to the average reference values (ARVs) of the CCT-K3. Korea Research Institute of Standards and Science (KRISS, Republic of Korea) provided the linkage to the CCT-K3 for temperatures ranging from -38.8344 °C to 419.527 °C. In the APMP.T-K3.4, two standard platinum resistance thermometers (SPRTs) were chosen as the transfer instruments and were calibrated at the ITS-90 fixed-points in the comparison range. The fixed-points in this comparison included Zn freezing point (419.527 °C), Sn freezing point (231.928 °C), In freezing point (156.5985 °C), Ga melting point (29.7646 °C), and Hg triple point (-38.8344 °C). The comparison was carried out in a participant-pilot-participant sequence where KRISS served as the pilot. The linkage was based on the fixed-point resistance ratios of RCM-LIPI relative to the ARVs of the CCT-K3 via the difference between the fixed-point resistance ratios of KRISS and the ARVs of the CCT-K3. The temperature differences between the national standards of RCM-LIPI and the ARVs of the CCT-K3 were within the evaluated comparison uncertainties of the ATPM.T-K3.4. This report provides detailed information on the comparison results, linkage mechanism, and the Degree of Equivalence of the RCM-LIPI relative to the institutes having participated in the CCT-K3. Main text To reach the main text of this paper, click on Final Report . Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/ . The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
ISSN:0026-1394
1681-7575