Proposition of Low-Cycle Fatigue Test Termination Criterion Based on Specimen Temperature Change

This paper presents proposition of the low-cycle fatigue test termination criterion based on specimen temperature change. The tests were performed using specimens made of G-X12CrMoVNbN9-1 (GP91) martensitic cast steel under axial tension-compression conditions with strain controlled at the total str...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Solid state phenomena 2016-04, Vol.250, p.114-119
Hauptverfasser: Lipski, Adam, Lis, Zbigniew
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This paper presents proposition of the low-cycle fatigue test termination criterion based on specimen temperature change. The tests were performed using specimens made of G-X12CrMoVNbN9-1 (GP91) martensitic cast steel under axial tension-compression conditions with strain controlled at the total strain amplitude levels amounting to εac = 0.25%, 0.5% and 0.6%. Very good compliance of the proposed criterion with the criterion used so far was obtained. The discrepancy for the tested material has not exceeded 2% in the εac stress range not exceeding 0.5%.
ISSN:1012-0394
1662-9779
1662-9779
DOI:10.4028/www.scientific.net/SSP.250.114