Background The radiation risk of patients undergoing invasive cardiology remains considerable and includes skin injuries and cancer. To date, submillisievert coronary angiography has not been considered feasible. Patients and methods In 2011, we compared results from 100 consecutive patients undergo...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Herz 2015-05, Vol.40 (Suppl 3), p.233-239
Hauptverfasser: Kuon, E., Weitmann, K., Hummel, A., Dörr, M., Reffelmann, T., Riad, A., Busch, M.C., Felix, S.B., Hoffmann, W., Empen, K.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background The radiation risk of patients undergoing invasive cardiology remains considerable and includes skin injuries and cancer. To date, submillisievert coronary angiography has not been considered feasible. Patients and methods In 2011, we compared results from 100 consecutive patients undergoing elective coronary angiography using the latest-generation flat-panel angiography system (FPS) with results from examinations by the same operator using 106 historic controls with a conventional image-intensifier system (IIS) that was new in 2002. Results The median patient exposure parameters were measured as follows: dose–area product (DAP) associated with radiographic cine acquisitions (DAP R ) and fluoroscopy (DAP F ) scenes, radiographic frames and runs, and cumulative exposure times for radiography and fluoroscopy. On the FPS as compared to the traditional IIS, radiographic detector entrance dose levels were reduced from 164 to 80 nGy/frame and pulse rates were lowered from 12.5/s to 7.5/s during radiography and from 25/s to 4/s during fluoroscopy. The cardiologist’s performance patterns remained comparable over the years: fluoroscopy time was constant and radiography time even slightly increased. Overall patient DAP decreased from 7.0 to 2.4 Gy × cm 2 ; DAP R , from 4.2 to 1.7 Gy × cm 2 ; and DAP F , from 2.8 to 0.6 Gy × cm 2 . Time-adjusted DAP R /s decreased from 436 to 130 mGy × cm 2 and DAP F /s, from 21.6 to 4.4 mGy × cm 2 . Cumulative patient skin dose with the FPS amounted to 67 mGy, and the median (interquartile range) of effective dose was 0.5 (0.3 … 0.7) mSv. Conclusion Consistent application of radiation-reducing techniques with the latest-generation flat-panel systems enables submillisievert coronary angiography in invasive cardiology.
ISSN:0340-9937
1615-6692
DOI:10.1007/s00059-013-4015-8