Acute Hydrophilic-Polymer Nephropathy and Acute Renal Failure
This letter reports a case of acute kidney injury and hydrophilic polymer emboli to the kidneys after a vascular intervention, findings that suggest that iatrogenic embolization of coating from stents may occur. To the Editor: Hydrophilic coatings are used on intravascular devices to facilitate mani...
Gespeichert in:
Veröffentlicht in: | The New England journal of medicine 2015-04, Vol.372 (18), p.1775-1776 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This letter reports a case of acute kidney injury and hydrophilic polymer emboli to the kidneys after a vascular intervention, findings that suggest that iatrogenic embolization of coating from stents may occur.
To the Editor:
Hydrophilic coatings are used on intravascular devices to facilitate manipulation and to minimize complications such as vasospasm during a procedure and thrombosis after a procedure.
1
,
2
We report a case of vascular intervention associated with acute renal failure in a 42-year-old woman.
In 2009, the patient underwent renal transplantation in which the renal artery was implanted into right external iliac artery. Between January and June 2013, her serum creatinine level increased progressively over a 5-month period, from a baseline value of 1.0 mg per deciliter to 2.2 mg per deciliter (normal range, 0.5 to 1.2 mg per . . . |
---|---|