Oral rapamycin to prevent human coronary stent restenosis: A pilot study

Recent human trials with rapamycin-eluting stents have shown very low restenosis rates. However, the high costs of these devices preclude their use in routine angioplasty, especially when considering multiple stenting. We evaluated whether orally administered rapamycin inhibits in-stent neointimal g...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The American heart journal 2004-08, Vol.148 (2), p.341-343
Hauptverfasser: Guarda, Eduardo, Marchant, Eugenio, Fajuri, Alejandro, Martínez, Alejandro, Morán, Sergio, Mendez, Manuel, Uriarte, Polentzi, Valenzuela, Edith, Lazen, Rosa
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Recent human trials with rapamycin-eluting stents have shown very low restenosis rates. However, the high costs of these devices preclude their use in routine angioplasty, especially when considering multiple stenting. We evaluated whether orally administered rapamycin inhibits in-stent neointimal growth in patients with unstable angina. We enrolled 15 patients successfully treated with the implantation of a single stent in a single de novo lesion in native coronary arteries. Correct stent expansion and apposition were corroborated with intravascular ultrasound scanning in all patients. Patients received aspirin, clopidogrel, and atorvastatin for 6 months. Rapamycin was administered in a loading dose of 5 mg, followed by 2 mg/day for 4 weeks. The reference diameter was 3.4 ± 0.4 mm, lesion length was 11.2 ± 2 mm, lesion type B1 was 36%, and lesion type B2 was 64%. After the procedure, in-stent minimal lumen diameter and diameter stenosis (DS) were 3.3 ± 0.4 mm and 0.3% ± 7.5%, respectively. At 10 days, plasma levels of rapamycin were 7.95 ± 2.6 ng/mL. At 6 months, angiographic determinations demonstrated an in-stent minimal lumen diameter of 2 ± 1 mm, an in-stent DS of 41.3% ± 28.0%, and an in-stent late loss of 1.4 ± 1.1 mm. Binary restenosis (>50% DS) was present in 6 of 15 patients (40%). Target lesion revascularization (coronary artery bypass grafting) was performed in 2 of 15 patients (13.3%). There were no serious adverse events during the 6-month period of follow-up, but 1 patient had severe heartburn caused by esophagitis, and another patient had herpes zoster at the end of the protocol. Oral rapamycin was well tolerated, but did not suppress in-stent neointimal growth in this small group of patients.
ISSN:0002-8703
1097-6744
DOI:10.1016/j.ahj.2004.03.046