The IHI flue gas desulfurization system was completed for a new 700 MW coalfired boiler in December 1995. The system is now operating very smoothly, achieving a removal efficiency of more than 90% for SO2 and more than 85% for particulates. 100% availability has been maintained so far. Special featu...
Gespeichert in:
Veröffentlicht in: | JSME International Journal Series B Fluids and Thermal Engineering 1998/11/15, Vol.41(4), pp.1023-1028 |
---|---|
1. Verfasser: | |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The IHI flue gas desulfurization system was completed for a new 700 MW coalfired boiler in December 1995. The system is now operating very smoothly, achieving a removal efficiency of more than 90% for SO2 and more than 85% for particulates. 100% availability has been maintained so far. Special features of the system are as follows: 1.A simultaneous SO2 and particulates removal absorber with a forced oxidation system is used, which is the largest spray tower ever built in Japan. 2.Two variable pitch axial flow fans are positioned downstream of the absorber(C-Position). 3.Optimum FGD control system is installed to minimize the operating cost for AFC(automatic frequency control) operation of the power plant. |
---|---|