Evaluation of simple and easy method for the preparation of a standard gas of volatile organic compounds from their mixed solution
Round-robin tests were conducted in order to investigate a simple and easy method for preparing a standard gas mixture of volatile organic hazardous air pollutants from their mixed solution by 16 members of the Association for Environmental Analysis in Osaka. Seven compounds (acrylonitrile, dichloro...
Gespeichert in:
Veröffentlicht in: | Bunseki kagaku 1999-01, Vol.48 (1), p.121 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Round-robin tests were conducted in order to investigate a simple and easy method for preparing a standard gas mixture of volatile organic hazardous air pollutants from their mixed solution by 16 members of the Association for Environmental Analysis in Osaka. Seven compounds (acrylonitrile, dichloromethane, chloroform, 1, 2-dichloroethane, benzene, trichloroethylene, and tetrachloroethylene) were accurately weighed into a vial one by one. An aliquot of this liquid mixture was transferred into a glass vessel (1 or 21) using a microsyringe, and then vaporized. The resulting gas mixtures (about 300 ppm each) were evaluated as a first standard gas by gas chromatography. The obtained results prove this method to be accurate and precise for the preparation of a standard gas mixture. |
---|---|
ISSN: | 0525-1931 |