At the sewage temperatures of 7-15°C, it used biological video microscopy and scanning electron microscopy to detect activated sludge morphology, miniature animals and flora species in northern winter sewage treatment plant. The results showed that activated sludge had dense floc with sharp edge, an...
Gespeichert in:
Veröffentlicht in: | Applied Mechanics and Materials 2013-08, Vol.361-363, p.1032-1035 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | At the sewage temperatures of 7-15°C, it used biological video microscopy and scanning electron microscopy to detect activated sludge morphology, miniature animals and flora species in northern winter sewage treatment plant. The results showed that activated sludge had dense floc with sharp edge, and was bigger at the temperatures of 13 and 15°C than at the temperatures of 7, 9 and 11°C. When the autumn and winter seasons were alternate and the sewage temperature was instability, the edge of the floc was slightly fuzzy and there was a small amount of free bacteria in activated sludge floc. The study had also shown that the temperature was higher, the type of sludge miniature animal and flora species were richer. |
---|---|