Effect of Relative Height between Water Tank and Collector on Performance of Thermosyphon Solar Water Heater

The effect of relative height between the bottom of the tank and the top of the collector on performance has been studied both theoreticaly and experimentally. According to the national testing standard methods, the efficiency of the system was tested. The results show that the simulation results ar...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Applied Mechanics and Materials 2011-07, Vol.71-78, p.2736-2739
Hauptverfasser: Shi, You Ming, Wei, Sheng Xian, Yan, Cui Qiong
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The effect of relative height between the bottom of the tank and the top of the collector on performance has been studied both theoreticaly and experimentally. According to the national testing standard methods, the efficiency of the system was tested. The results show that the simulation results are in good accordance with the experimental ones. The data indicate that the optimum value of relative height is 0.74m with the maximum efficiency of 67.7% for the system with a total area of 1.5m2 and storage water tank capacity of 120L. Increasing or decreasing the relative height within a range of 0.3m has no significant effect on thermal efficiency.
ISSN:1660-9336
1662-7482
1662-7482
DOI:10.4028/www.scientific.net/AMM.71-78.2736