The Analysis of Judging Criterion and the Influence of Shear-Span Ratio to the Failure Model in Frame Short Column
In architectural design, the discrimination to the frame short column has two judging criteria: the judging criterion with the shear-span ratio λ«2 and the judging criterion with the height-width ratio H/h«4 . Whether they have consistency has been raised attention by the engineering personnel. Thro...
Gespeichert in:
Veröffentlicht in: | Applied Mechanics and Materials 2011-09, Vol.94-96, p.913-917 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | In architectural design, the discrimination to the frame short column has two judging criteria: the judging criterion with the shear-span ratio λ«2 and the judging criterion with the height-width ratio H/h«4 . Whether they have consistency has been raised attention by the engineering personnel. Through the analysis of two judging criteria, We get that: the judging criterion λ«2 has extensive applicability; the judging criterion H/h«4 is the simple calculation method, and needs certain limitations. Meanwhile, by the analysis of the relationship between the shear-span ratio and the mechanical properties in frame short column, it is concluded that the shear-span ratio has the directly affect to the failure model, and the circular cross-section frame column has better mechanical properties. |
---|---|
ISSN: | 1660-9336 1662-7482 1662-7482 |