The aseismatic strengthening technique for masonry structure was researched in this paper. The seismic response of a L-type school building with and without isolation system were computed by using software SAP2000. The isolation system were made up of lead rubber bearings or combined Isolation syste...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Applied Mechanics and Materials 2011-09, Vol.94-96, p.1298-1303
Hauptverfasser: Fan, Xi Sen, Ren, Shu Zhen
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The aseismatic strengthening technique for masonry structure was researched in this paper. The seismic response of a L-type school building with and without isolation system were computed by using software SAP2000. The isolation system were made up of lead rubber bearings or combined Isolation system. The results showed that base-isolated strengthening can reduce not only the translational response but also the torsional response with earthquake. The combined Isolation system was more effetive in decreasing translational response than the lead rubber bearing, but inferior to in decreasing torsion response.