Optimizing Research on the Clad Façade of a High-Rise Building Using CFD Method

Using Airpak as CFD tool, the study simulates and analyses how the openings and thermal characteristics of the clad façade work on the distribution of temperature and ventilation in the atrium of a high-rise building in Shenzhen. The result shows that, with the atrium roof open to the air, openings...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Applied Mechanics and Materials 2012-08, Vol.193-194, p.1284-1289
Hauptverfasser: Shao, Li Li, Yuan, Lei, Xu, Xue Song
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Using Airpak as CFD tool, the study simulates and analyses how the openings and thermal characteristics of the clad façade work on the distribution of temperature and ventilation in the atrium of a high-rise building in Shenzhen. The result shows that, with the atrium roof open to the air, openings on the lower part of the clad façade can significantly improve air ventilation and reduce the temperature in the atrium in summer. It is also found that clad glazing of large U-value and large SHGC helps to release the residual heat in the atrium, which make laminated glass made of clear float glass smart choice for the clad glazing of the building.
ISSN:1660-9336
1662-7482
1662-7482
DOI:10.4028/www.scientific.net/AMM.193-194.1284