Structural Defects of Existing RC Buildings in Eskisehir Province
In this study, structural defects of existing 709 reinforced concrete (RC) buildings in Eskisehir Province were represented. Structural defects such as gaps between adjacent buildings, strong beam-weak column, mezzanine floor, short column, corner column, discontinuous frame, anchorage beams, long s...
Gespeichert in:
Veröffentlicht in: | Applied Mechanics and Materials 2012-01, Vol.147, p.145-148 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | In this study, structural defects of existing 709 reinforced concrete (RC) buildings in Eskisehir Province were represented. Structural defects such as gaps between adjacent buildings, strong beam-weak column, mezzanine floor, short column, corner column, discontinuous frame, anchorage beams, long span, segregation, corrosion, inconvenient column/beam lateral reinforcement, low concrete strength and inconvenient steel reinforcement were determined in the study. It was determined that %35 of existing buildings have discontinuous frame, %16 of them have long span problem. It was also observed that nearly %40 of the buildings have no column/beam lateral reinforcement and %70 of them have inadequate gaps. |
---|---|