Isolation on the Top of Columns of a Building Analysis Based on ETABS

Taking a practical five-story frame-structure with opening floor as background, the finite element analysis software ETABS is used to perform analysis of the first-floor isolation. Time-history analysis for the structures showed that, vibration reduction effect of the superstructure is obvious under...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Applied Mechanics and Materials 2012-05, Vol.174-177, p.1994-2000
Hauptverfasser: Zhu, Jian Hui, Huang, Ying, Wang, Yun Xun, Huang, Peng Yun, Wu, Ying Xiong
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Taking a practical five-story frame-structure with opening floor as background, the finite element analysis software ETABS is used to perform analysis of the first-floor isolation. Time-history analysis for the structures showed that, vibration reduction effect of the superstructure is obvious under 7 degree earthquakes. The substructure (isolated columns) is still in elastic deformation stage under 7 degree rare earthquakes, which proves that isolation technology on the top of columns can improve the seismic behavior of the first-floor weak frame-structure. Meanwhile, mechanical analyses and seismic design of the isolated columns are performed. The results indicated that rational design ensures the structure’s seismic safety.
ISSN:1660-9336
1662-7482
1662-7482
DOI:10.4028/www.scientific.net/AMM.174-177.1994