Electrical Erosion Characteristics of Pt-Ir-Zr Alloy Contact under DC Load
The analysis of electrical erosion characteristics of contacts under DC load is conducive to the in-depth study of the arc erosion mechanism. Through the electrical contact experiment, the electrical erosion status of the Pt-Ir-Zr alloy under DC load of 25V/15A is studied in this paper. The results...
Gespeichert in:
Veröffentlicht in: | Applied Mechanics and Materials 2013-09, Vol.395-396, p.191-195 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The analysis of electrical erosion characteristics of contacts under DC load is conducive to the in-depth study of the arc erosion mechanism. Through the electrical contact experiment, the electrical erosion status of the Pt-Ir-Zr alloy under DC load of 25V/15A is studied in this paper. The results show that: the contacts have excellent anti-welding behavior and lower loss on arc ablation. The separation acceleration of the breaking process between the movable and static contacts is 154.32μm/ms2. The arc erosion surfaces of the material show a large number of paste-like coagulum and bubbles. There are some micro-cracks existing on the surface of the Pt-Ir-Zr alloy contacts. The obvious material transfer phenomenon occurs between the movable and static contacts under DC load. |
---|---|
ISSN: | 1660-9336 1662-7482 1662-7482 |
DOI: | 10.4028/www.scientific.net/AMM.395-396.191 |