The Principle and Calibration of the Third Gear Flow-Meter
At present, the domestic development of the gear flow-meter is far behind the developed countries, especially in the micro gear flow-meter. This paper proposes a typical structure named the third gear flow-meter. The structural characteristics and working principle of the third gear flow-meter was i...
Gespeichert in:
Veröffentlicht in: | Applied Mechanics and Materials 2013-09, Vol.397-400, p.1713-1717 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | At present, the domestic development of the gear flow-meter is far behind the developed countries, especially in the micro gear flow-meter. This paper proposes a typical structure named the third gear flow-meter. The structural characteristics and working principle of the third gear flow-meter was introduced in detail, the prototype of the third gear flow-meter was designed and processed, and the calibration tests and pressure experiments of the third gear flow-meter prototype was made at last. We can draw that the three gear flow-meter can be used in hydraulic system pressure range is less than 25Mpa, the flow rate was 0.15~0.2m3/h can meet the high requirements of the stability of measurement, and the measurement accuracy in the whole flow range is 0.2 class. This article provides a reliable experimental data for the design of the micro gear flow-meter. |
---|---|
ISSN: | 1660-9336 1662-7482 1662-7482 |
DOI: | 10.4028/www.scientific.net/AMM.397-400.1713 |