The Principle and Calibration of the Third Gear Flow-Meter

At present, the domestic development of the gear flow-meter is far behind the developed countries, especially in the micro gear flow-meter. This paper proposes a typical structure named the third gear flow-meter. The structural characteristics and working principle of the third gear flow-meter was i...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Applied Mechanics and Materials 2013-09, Vol.397-400, p.1713-1717
Hauptverfasser: Tang, Cun Ren, Zhang, Jun, Niu, Meng Meng, Tang, Hong Mei, Li, Xian Hua
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:At present, the domestic development of the gear flow-meter is far behind the developed countries, especially in the micro gear flow-meter. This paper proposes a typical structure named the third gear flow-meter. The structural characteristics and working principle of the third gear flow-meter was introduced in detail, the prototype of the third gear flow-meter was designed and processed, and the calibration tests and pressure experiments of the third gear flow-meter prototype was made at last. We can draw that the three gear flow-meter can be used in hydraulic system pressure range is less than 25Mpa, the flow rate was 0.15~0.2m3/h can meet the high requirements of the stability of measurement, and the measurement accuracy in the whole flow range is 0.2 class. This article provides a reliable experimental data for the design of the micro gear flow-meter.
ISSN:1660-9336
1662-7482
1662-7482
DOI:10.4028/www.scientific.net/AMM.397-400.1713