PET Imaging of High-Affinity [alpha]4[Beta]2 Nicotinic Acetylcholine Receptors in Humans with ^sup 18^F-AZAN, a Radioligand with Optimal Brain Kinetics

We evaluated (...)-2-(6-[...F]fluoro-2,3'-bipyridin-5'-yl)-7-methyl-7-aza-bicyclo[2.2.1]heptane (...F-AZAN), a novel radiotracer that binds to α4β2 nicotinic acetylcholine receptors (α4β2-nAChRs) and shows high specific binding and rapid and reversible kinetics in the baboon and human brai...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of nuclear medicine (1978) 2013-08, Vol.54 (8), p.1308
Hauptverfasser: Wong, Dean F, Kuwabara, Hiroto, Kim, Jongho, Brasic, James R, Chamroonrat, Wichana, Gao, Yongjun, Valentine, Heather, Willis, William, Mathur, Anil, McCaul, Mary E, Wand, Gary, Gean, Emily G, Dannals, Robert F, Horti, Andrew G
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:We evaluated (...)-2-(6-[...F]fluoro-2,3'-bipyridin-5'-yl)-7-methyl-7-aza-bicyclo[2.2.1]heptane (...F-AZAN), a novel radiotracer that binds to α4β2 nicotinic acetylcholine receptors (α4β2-nAChRs) and shows high specific binding and rapid and reversible kinetics in the baboon and human brain. We tested safety tolerability and test-retest reliability (n = 5) and proposed initial quantification of ...F-AZAN receptors in 3 healthy human subjects who had nicotine exposure and 9 who did not. We also present a receptor blocking study in a nicotine subject dosed with the α4β2-nAChR-selective partial agonist varenicline. Radiation dosimetry PET/CT experiments indicated that most human organs received doses between 0.008 and 0.015 mSv/MBq, with an effective dose of approximately 0.014 mSv/MBq. The tracer rapidly entered the brain, and the peak was reached before 20 min, even for thalamus. Ninety-minute scans were sufficient for ...F-AZAN to obtain the ratio at equilibrium of specifically bound radioligand to nondisplaceable radioligand in tissue (BP...) using plasma reference graphical analysis, which showed excellent reproducibility of BP... (test-retest variability < 10%) in the nAChR-rich brain regions. Regional plasma reference graphical analysis BP... values exceeded 2 in the midbrain tegmental nuclei, lateral geniculate body, and thalamus for nonsmokers (n = 9) but were less than 1 in the nAChR-poor brain regions. There was a dramatic reduction of ...F-AZAN brain uptake in smokers and varenicline-treated subjects. ...F-AZAN is a highly specific, safe, and effective PET radioligand for human subjects that requires only 90 min of PET scanning to estimate high-affinity α4β2-nAChR in the living human brain. (ProQuest: ... denotes formulae/symbols omitted.)
ISSN:0161-5505
1535-5667