Improvement of a Simple Evaluation Method for Duct Streaming by Taking Account of the Deep Penetration Component

A simplified formula for radiation streaming through bent ducts was previously derived by optics analogy, considering only components passing through the duct and without enormous preparatory calculations. Now, by taking account of deep penetrating component, the streaming formula is improved in ord...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of nuclear science and technology 2001-08, Vol.38 (8), p.583
Hauptverfasser: MAKI, Koichi, MORIMOTO, Yuichi, SHIBATA, Kei-ichiro
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A simplified formula for radiation streaming through bent ducts was previously derived by optics analogy, considering only components passing through the duct and without enormous preparatory calculations. Now, by taking account of deep penetrating component, the streaming formula is improved in order to estimate not only γ-ray flux but also neutron flux with accuracy, factor 2-3, applicable to preliminary shielding designs. Dose rates at the exit estimated by the improved formula are compared with experimental values. As for γ-ray evaluated values become conservative by improvement, while evaluated values were underestimated before improvement. Also for neutron, the discrepancy between the calculated values by the present formula and observed ones becomes within factor 2 after improvement from factor 3 before improvement. From these results, it is concluded that the improved formula is applicable to preliminary shielding designs.
ISSN:0022-3131
1881-1248
DOI:10.3327/jnst.38.583