Auxiliary Switch Control of a Bidirectional Soft-Switching DC/DC Converter
In this paper, the auxiliary switch control using a lookup table is proposed to enhance the efficiency of the bidirectional dc/dc converter used in electric vehicle, which performs soft switching. Continuous current data are difficult to obtain during a resonant operation due to the limit of DSP ADC...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on power electronics 2013-12, Vol.28 (12), p.5446-5457 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | In this paper, the auxiliary switch control using a lookup table is proposed to enhance the efficiency of the bidirectional dc/dc converter used in electric vehicle, which performs soft switching. Continuous current data are difficult to obtain during a resonant operation due to the limit of DSP ADC capacity. The proposed auxiliary switch control has a lookup table reference of the auxiliary switch turn-on time. The control method properly controls the auxiliary switch turn-on time according to the required load current; this auxiliary switch control brings the more efficient control in generative and regenerative mode operation. The proposed approach has been validated by the results of experiments on a bidirectional dc/dc converter, inverter, and interior permanent magnet synchronous motor. |
---|---|
ISSN: | 0885-8993 1941-0107 |
DOI: | 10.1109/TPEL.2013.2254131 |