Radiation Dose from Computed Tomography in Patients with Necrotizing Pancreatitis: How Much Is Too Much?

Objectives Low-dose ionizing radiation from medical imaging has been indirectly linked with subsequent cancer. Computed tomography (CT) is the gold standard for defining pancreatic necrosis. The primary goal was to identify the frequency and effective radiation dose of CT imaging for patients with n...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of gastrointestinal surgery 2010-10, Vol.14 (10), p.1529-1535
Hauptverfasser: Ball, Chad G., Correa-Gallego, Camilo, Howard, Thomas J., Zyromski, Nicholas J., House, Michael G., Pitt, Henry A., Nakeeb, Atilla, Schmidt, Christian M., Akisik, Fatih, Lillemoe, Keith D.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Objectives Low-dose ionizing radiation from medical imaging has been indirectly linked with subsequent cancer. Computed tomography (CT) is the gold standard for defining pancreatic necrosis. The primary goal was to identify the frequency and effective radiation dose of CT imaging for patients with necrotizing pancreatitis. Methods All patients with necrotizing pancreatitis (2003–2007) were retrospectively analyzed for CT-related radiation exposure. Results Necrosis was identified in 18% (238/1290) of patients with acute pancreatitis (mean age = 53 years; hospital/ICU length of stay = 23/7 days; mortality = 9%). A median of five CTs/patient [interquartile range (IQR) = 4] were performed during a median 2.6-month interval. The average effective dose was 40 mSv per patient (equivalent to 2,000 chest X-rays; 13.2 years of background radiation; one out of 250 increased risk of fatal cancer). The actual effective dose was 63 mSv considering various scanner technologies. CTs were infrequently (20%) followed by direct intervention (199 interventional radiology, 118 operative, 12 endoscopic) (median = 1; IQR = 2). Magnetic resonance imaging did not have a CT-sparing effect. Mean direct hospital costs increased linearly with CT number ( R  = 0.7). Conclusions The effective radiation dose received by patients with necrotizing pancreatitis is significant. Management changes infrequently follow CT imaging. The ubiquitous use of CT in necrotizing pancreatitis raises substantial public health concerns and mandates a careful reassessment of its utility.
ISSN:1091-255X
1873-4626