Optimization of tube potential-filter combinations for film-screen mammography a contrast detail phantom study

This study evaluated how tube potential-filter combinations [with a molybdenum (Mo) anode and either an Mo or a rhodium (Rh) filter] influence image quality and radiation dose to breasts of different thicknesses in film-screen mammography using a new mammography phantom (CDMAM Phantom Type 3.4). A 2...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Clinical imaging 2005-07, Vol.29 (4), p.246-250
Hauptverfasser: CHIDA, Koichi, ZUGUCHI, Masayuki, SAI, Masahiro, SAITO, Haruo, YAMADA, Takayuki, ISHIBASHI, Tadashi, ITO, Daisuke, KIMOTO, Nobumitsu, KOHZUKI, Masahiro, TAKAHASHI, Shoki
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This study evaluated how tube potential-filter combinations [with a molybdenum (Mo) anode and either an Mo or a rhodium (Rh) filter] influence image quality and radiation dose to breasts of different thicknesses in film-screen mammography using a new mammography phantom (CDMAM Phantom Type 3.4). A 28-kVp/Mo tube potential-filter combination is recommended for a breast (phantom) thickness of 40 mm or less, 28 kVp/Rh for a breast (phantom) thickness of 60 mm or less, and 30 kVp/Rh for a breast (phantom) thickness greater than 60 mm.
ISSN:0899-7071
1873-4499
DOI:10.1016/j.clinimag.2004.11.003