Validation of direct CT measurement of malrotation in femoral neck fractures: A bone model study

While postoperative malrotation in the subtrochanteric region is a well-known problem, malrotation after osteosynthesis in proximal femoral fractures has not been extensively studied. In this context, many methods for perioperatively assessment of femoral torsion have been described, but none of the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:PloS one 2023-04, Vol.18 (4), p.e0278850-e0278850
Hauptverfasser: Liodakis, Emmanouil, Pöhler, Gesa Helen, Sonnow, Lena, Mommsen, Philipp, Clausen, Jan-Dierk, Graulich, Tilman, Maslaris, Alexander, Omar, Mohamed, Stübig, Timo, Sehmisch, Stephan, Omar Pacha, Tarek
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:While postoperative malrotation in the subtrochanteric region is a well-known problem, malrotation after osteosynthesis in proximal femoral fractures has not been extensively studied. In this context, many methods for perioperatively assessment of femoral torsion have been described, but none of them is applicable in the basicervical region of the proximal femur. As an important difference in femoral neck fractures, the discontinuous neck fails to serve as a significant "pointer" for measurements and malfunctions to be placed in relation to the condylar plane. Considering postoperative maltorsion at any location as a substantial negative effect on patients' outcome and functional expectations, precise and patient-friendly rotation measurement standards in femoral neck fractures are desired in clinical practice. Recently, a novel computed tomography (CT) based geometric technique was described named "direct measurement" with promising results covering this diagnostic disparity, but still requires validation. Thus, we aimed to validate the previously described technique using a controlled range of displacement in a femoral neck fracture Sawbone® model. A goniometer was designed to set retro- and anteversion of the proximal femur in a reproducible manner. Prospectively, all femurs underwent a CT scan and were measured 3D for displacement. The interclass correlation between the CT measurements and the goniometer measurements was calculated and was found to be very high (1.00, 95% confidence interval: 0.99-1.00; p < 0.001). For the mean of all measurements, the Pearson's correlation was 1.00 (p < 0.001). No significant differences in the measurements of both investigators were observed, with 20° of retroversion not significant (-1.20 ± 1.71; 95% confidence interval: -2.43-0.03; p = 0.054). This CT-based 3D measurement technique may allow for perioperative malrotation assessment in basicervical femoral neck fractures and appears to be feasible in femoral neck fractures when it comes to rare cases of osteosynthesis. Further investigations are still needed to define the thresholds of malrotation provoking functional impairment after osteosynthesis in basicervical femoral neck fractures.
ISSN:1932-6203
1932-6203
DOI:10.1371/journal.pone.0278850