New chest compression method in infant resuscitation: Cross thumb technique

Background The two-thumb encircling technique (2TT) is superior to the two-finger technique (2FT) in infant cardiopulmonary resuscitation (CPR), but there are difficulties in providing ventilation as soon as possible. We modified the 2TT to the cross-thumb technique (CTT) to maintain good CPR perfor...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:PloS one 2022-08, Vol.17 (8), p.e0271636-e0271636
Hauptverfasser: Jeon, Woochan, Kim, Jungeon, Ko, Yura, Lee, Jisook
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background The two-thumb encircling technique (2TT) is superior to the two-finger technique (2FT) in infant cardiopulmonary resuscitation (CPR), but there are difficulties in providing ventilation as soon as possible. We modified the 2TT to the cross-thumb technique (CTT) to maintain good CPR performance at the same position as 2FT. We aimed to compare the quality of chest compression and brief hands-off times in 2FT, 2TT, and CTT by a single rescuer using an infant CPR manikin model. Methods This study was designed as a prospective randomized controlled simulation-based study. We used the Resusci® Baby QCPR (Laerdal Medical, Stavanger, Norway) as a simulated 3-month-old infant. Ventilation was performed by the mouth-to-mouth technique using a chest compression-to-ventilation ratio of 30:2 as a single rescuer. Data on CPR quality, such as locations, rates, depth and release of chest compressions, hands-off times, and proper ventilation, were recorded using the Resusci® Baby QCPR and SkillReporter. Also, the chest compression fraction (CCF) was automatically calculated. Results The depth of chest compression in 2FT, 2TT, and CTT were 40.0 mm (interquartile range [IQR] 39.0, 41.0), 42.0 mm (IQR 41.0, 43.0), and 42.0 mm (IQR 41.0, 43.0), respectively. The depth of chest compression in 2FT was shallower than that in the other two techniques (P
ISSN:1932-6203
1932-6203