Fit-for-purpose quantitative liquid biopsy based droplet digital PCR assay development for detection of programmed cell death ligand-1 (PD-L1) RNA expression in PAXgene blood samples
Development of a clinically applicable liquid biopsy-based test for PD-L1 mRNA expression would be beneficial in providing complementary evidence to current immunohistochemistry assays. Hence, we report the development of a fit-for-purpose assay for detection of blood PD-L1 mRNA expression using dro...
Gespeichert in:
Veröffentlicht in: | PloS one 2021-05, Vol.16 (5), p.e0250849-e0250849 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Development of a clinically applicable liquid biopsy-based test for PD-L1 mRNA expression would be beneficial in providing complementary evidence to current immunohistochemistry assays. Hence, we report the development of a fit-for-purpose assay for detection of blood PD-L1 mRNA expression using droplet digital polymerase chain reaction (ddPCR). TaqMan® assays were selected based on coverage of the PD-L1 gene and were tested for linearity and efficiency using real-time quantitative PCR. Four reference genes were analyzed in positive control cell line (A549 treated with interferon gamma, [IFN γ]) genomic DNA. The PD-L1 primer/probe sets were also evaluated in ddPCR for limit of blank, limit of detection, and precision. Finally, thirty-five healthy volunteer samples were evaluated to establish a baseline level of PD-L1 expression. In ddPCR, the limit of blank was determined to be 0 copies and the limit of detection was determined to be less than or equal to 19 copies of PD-L1. The average intra-run coefficient of variation in the ddPCR assay was 7.44% and average inter-run CV was 7.70%. Treatment of A549 cells with IFN γ resulted in a 6.7-fold increase in PD-L1 expression (21,580 copies in untreated cDNA versus 145,000 copies in treated cDNA). Analysis of healthy human samples yielded a median value of 1659 PD-L1 copies/μL with a range of 768-7510 copies/μL. The assay was transferred to an external service provider and results from our in-house experiments and those conducted externally shows a correlation of 0.994. In conclusion, a fit-for-purpose liquid biopsy-based, purely quantitative ddPCR assay for the detection of PD-L1 mRNA expression was developed and validated using PAXgene RNA blood samples. Linearity, reproducibility, limit of blank and limit of detection were measured and deemed suitable for clinical application. This ultra-sensitive liquid biopsy ddPCR assay has promising clinical potential in screening, longitudinal monitoring and disease progression detection. |
---|---|
ISSN: | 1932-6203 1932-6203 |
DOI: | 10.1371/journal.pone.0250849 |