Diagnostic accuracy of antigen detection in urine and molecular assays testing in different clinical samples for the diagnosis of progressive disseminated histoplasmosis in patients living with HIV/AIDS: A prospective multicenter study in Mexico

The progressive disseminated histoplasmosis (PDH) has been associated with severe disease and high risk of death among people living with HIV (PLWHIV). Therefore, the purpose of this multicenter, prospective, double-blinded study done in ten Mexican hospitals was to determine the diagnostic accuracy...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:PLoS neglected tropical diseases 2021-03, Vol.15 (3), p.e0009215-e0009215
Hauptverfasser: Martínez-Gamboa, Areli, Niembro-Ortega, María Dolores, Torres-González, Pedro, Santiago-Cruz, Janeth, Velázquez-Zavala, Nancy Guadalupe, Rangel-Cordero, Andrea, Crabtree-Ramírez, Brenda, Gamboa-Domínguez, Armando, Reyes-Gutiérrez, Edgardo, Reyes-Terán, Gustavo, Lozano-Fernandez, Víctor Hugo, Ahumada-Topete, Víctor Hugo, Martínez-Ayala, Pedro, Manríquez-Reyes, Marisol, Ramírez-Hinojosa, Juan Pablo, Rodríguez-Zulueta, Patricia, Hernández-León, Christian, Ruíz-Quiñones, Jesús, Rivera-Martínez, Norma Eréndira, Chaparro-Sánchez, Alberto, Andrade-Villanueva, Jaime, González-Hernández, Luz Alicia, Cruz-Martínez, Sofia, Flores-Barrientos, Oscar, Gaytán-Martínez, Jesús Enrique, Magaña-Aquino, Martín, Cervantes-Sánchez, Axel, Olivas-Martínez, Antonio, Araujo-Meléndez, Javier, Del Rocío Reyes-Montes, María, Duarte-Escalante, Esperanza, Frías-De León, María Guadalupe, Ramírez, José Antonio, Taylor, María Lucia, de León-Garduño, Alfredo Ponce, Sifuentes-Osornio, José
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The progressive disseminated histoplasmosis (PDH) has been associated with severe disease and high risk of death among people living with HIV (PLWHIV). Therefore, the purpose of this multicenter, prospective, double-blinded study done in ten Mexican hospitals was to determine the diagnostic accuracy of detecting Histoplasma capsulatum antigen in urine using the IMMY ALPHA Histoplasma EIA kit (IAHE), clarus Histoplasma GM Enzyme Immunoassay (cHGEI IMMY) and MiraVista Histoplasma Urine Antigen LFA (MVHUALFA); as well as the Hcp100 and 1281-1283220SCAR nested PCRs in blood, bone-marrow, tissue biopsies and urine. We included 415 PLWHIV older than 18 years of age with suspicion of PDH. Using as diagnostic standard recovery of H. capsulatum in blood, bone marrow or tissue cultures, or histopathological exam compatible, detected 108 patients (26%, [95%CI, 21.78-30.22]) with proven-PDH. We analyzed 391 urine samples by the IAHE, cHGEI IMMY and MVHUALFA; the sensitivity/specificity values obtained were 67.3% (95% CI, 57.4-76.2) / 96.2% (95% CI, 93.2-98.0) for IAHE, 91.3% (95% CI, 84.2-96.0) / 90.9% (95% CI, 87.0-94.0) for cHGEI IMMY and 90.4% (95% CI, 83.0-95.3) / 92.3% (95% CI, 88.6-95.1) for MVHUALFA. The Hcp100 nested PCR was performed on 393, 343, 75 and 297, blood, bone marrow, tissue and urine samples respectively; the sensitivity/specificity values obtained were 62.9% (95%CI, 53.3-72.5)/ 89.5% (95%CI, 86.0-93.0), 65.9% (95%CI, 56.0-75.8)/ 89.0% (95%CI, 85.2-92.9), 62.1% (95%CI, 44.4-79.7)/ 82.6% (95%CI, 71.7-93.6) and 34.9% (95%CI, 24.8-46.2)/ 67.3% (95%CI, 60.6-73.5) respectively; and 1281-1283220SCAR nested PCR was performed on 392, 344, 75 and 291, respectively; the sensitivity/specificity values obtained were 65.3% (95% CI, 55.9-74.7)/ 58.8% (95%CI, 53.2-64.5), 70.8% (95%CI, 61.3-80.2)/ 52.9% (95%CI, 46.8-59.1), 71.4% (95%CI, 54.7-88.2)/ 40.4% (95%CI, 26.4-54.5) and 18.1% (95%CI, 10.5-28.1)/ 90.4% (95%CI, 85.5-94.0), respectively. The cHGEI IMMY and MVHUALFA tests showed excellent performance for the diagnosis of PDH in PLWHIV. The integration of these tests in clinical laboratories will certainly impact on early diagnosis and treatment.
ISSN:1935-2735
1935-2727
1935-2735
DOI:10.1371/journal.pntd.0009215