Comparison of the change in QuantiFERON-TB Gold Plus and QuantiFERON-TB Gold In-Tube results after preventive therapy for latent tuberculosis infection
We investigated changes in the interferon-[gamma] levels before and after treatment of latent tuberculosis infection (LTBI) using QuantiFERON-TB Gold Plus (QFT-Plus) and QuantiFERON-TB Gold In-Tube (QFT-GIT) assays. The objective was to assess whether QFT-Plus could serve as a biomarker of LTBI trea...
Gespeichert in:
Veröffentlicht in: | PloS one 2020-06, Vol.15 (6), p.e0234700-e0234700 |
---|---|
Hauptverfasser: | , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We investigated changes in the interferon-[gamma] levels before and after treatment of latent tuberculosis infection (LTBI) using QuantiFERON-TB Gold Plus (QFT-Plus) and QuantiFERON-TB Gold In-Tube (QFT-GIT) assays. The objective was to assess whether QFT-Plus could serve as a biomarker of LTBI treatment response. We prospectively enrolled 44 individuals whose baseline QFT-GIT and QFT-Plus showed positive results at a tertiary referral center in South Korea between March 2017 and March 2018. The results of the QFT-Plus assay were defined as positive if either or both of the antigen tubes (TB1 and/or TB2) were positive. After LTBI treatment, both tests were repeated. The mean age of the participants was 47.6 years. The QFT-GIT and QFT-Plus assays revealed positive results in 42/44 (95.5%) and 41/44 (93.2%) participants after LTBI treatment, showing overall agreement of 93.2%, with a Cohen's kappa value of 0.37 (fair agreement). The differences between pre- and post-LTBI treatment interferon-[gamma] levels were measured using the QFT-GIT and QFT-Plus assays. No significant differences were noted among the 3 values: the median difference in interferon-[gamma] value with QFT-GIT, QFT-Plus TB1, and QFT-Plus TB2 was 0.211 IU/mL (IQR, -0.337-3.347), 0.025 IU/mL (IQR, -0.338-1.368), and 0.180 IU/mL (IQR, -0.490-2.278), respectively (P = 0.401). The change in interferon-[gamma] levels before and after LTBI treatment measured using the QFT-Plus assay showed a similar trend to that of the QFT-GIT assay. Considering that the QFT-GIT assay is not a useful biomarker of LTBI treatment response, QFT-Plus also appears not to be useful for this purpose. |
---|---|
ISSN: | 1932-6203 1932-6203 |
DOI: | 10.1371/journal.pone.0234700 |