Intraocular pressure according to different types of tonometry (non-contact and Goldmann applanation) in patients with different degrees of bilateral tearing

To investigate intraocular pressure (IOP) readings by non-contact tonometry (NCT) and Goldmann applanation tonometry (GAT) for patients with different degrees of bilateral tearing. In this study, we reviewed the medical charts of patients complaining of different degrees of bilateral tearing. The te...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:PloS one 2019-09, Vol.14 (9), p.e0222652-e0222652
Hauptverfasser: Seol, Bo Ram, Kang, Tae Gu, Gu, Bonhyeok
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:To investigate intraocular pressure (IOP) readings by non-contact tonometry (NCT) and Goldmann applanation tonometry (GAT) for patients with different degrees of bilateral tearing. In this study, we reviewed the medical charts of patients complaining of different degrees of bilateral tearing. The tear meniscus height (TMH) and IOP with NCT and GAT were measured. In each patient, a comparison of IOP readings between the eye with lower TMH and the contralateral eye with higher TMH was evaluated. The TMH was graded as follows: grade 1 (low): TMH < 0.2 mm; grade 2 (moderate): 0.2 mm ≤ TMH < 0.6 mm; grade 3 (high): TMH ≥ 0.6 mm. Subsequently, a comparison of IOP readings among eyes with low, moderate, and high TMH was also performed. A total of 120 eyes of 60 patients were enrolled. When comparing the two eyes of a patient, the eye with higher TMH showed higher NCT readings and larger difference in IOP readings between the two tonometries than the eye with lower TMH (P < 0.001 and P < 0.001, respectively). When TMH was classified into grades according to the degree, the high TMH eyes showed higher NCT readings than did the low and moderate TMH eyes (P < 0.001 and P = 0.001, respectively). In addition, the high TMH eyes showed a larger difference in IOP readings between the two tonometries than did the low and moderate TMH eyes (P < 0.001 and P < 0.001, respectively). Eyes with higher TMH showed higher NCT readings and a larger difference in IOP between the two tonometries (NCT and GAT) than those with lower TMH. In patients with tearing, the NCT value may be inaccurate, so it is necessary to measure the GAT.
ISSN:1932-6203
1932-6203
DOI:10.1371/journal.pone.0222652