Results of using robotic-assisted navigational system in pedicle screw placement

Recent technical developments have resulted in robotic-assisted pedicle screw placement techniques. However, the use of robotic-assisted navigational techniques is still subject to controversy. This study aims to assess the accuracy and safety of a self-developed navigation system, the point spine n...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:PloS one 2019-08, Vol.14 (8), p.e0220851-e0220851
Hauptverfasser: Chen, Hsuan-Yu, Xiao, Xiu-Yun, Chen, Chih-Wei, Chou, Hao-Kai, Sung, Chen-Yu, Lin, Feng-Huei, Chen, Po-Quang, Wong, Tze-Hong
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Recent technical developments have resulted in robotic-assisted pedicle screw placement techniques. However, the use of robotic-assisted navigational techniques is still subject to controversy. This study aims to assess the accuracy and safety of a self-developed navigation system, the point spine navigation system (PSNS), for robotic-assisted pedicle screw placement surgery. Fifty-nine pedicle screws were implanted in three porcine vertebrae at the T6-T10 and L1-L5 levels, with the assistance of the PSNS. The navigation and planning system provides virtual surgical guide images, including sagittal, coronal, axial, oblique planes, and customized three-dimensional reconstructions for each vertebra to establish accurate pedicle screw trajectories and placement tracts. After pedicle screw placement, post-operative spiral computer tomographic scans were performed and screws were evaluated using the Gertzbein-Robbins classification. Differences between the actual pedicle screw position and pre-operative planning paths, including the angle, shortest distance, and entry trajectory were recorded. The 59 pedicle screw placements were all within a safe zone, and there was no spinal canal perforation or any other damage under postoperative computed tomography image data. Fifty-one screws were categorized as group A, seven screws were noted as group B, and one screw was identified as group E under the Gertzbein-Robbins classification. The mean entry point deviation was 2.71 ± 1.72°, mean trajectory distance was 1.56 ± 0.66 mm, and average shortest distance between two paths was 0.96 ± 0.73 mm. Pedicle placement remains a challenging procedure with high reported incidences of nerve and vascular injuries. The implementation of a robotic-assisted navigational system yields an acceptable level of accuracy and safety for the pedicle screw placement surgery.
ISSN:1932-6203
1932-6203
DOI:10.1371/journal.pone.0220851